NYC-WTC_000293768
TEM-based asbestos analysis with SAED/EDS for exterior/interior of building.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Asbestos fiber analysis by TEM for New Stuyvesant High School, received 12/22/01.
NYC-WTC_000270713OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc.' 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879' 28-11 Queens Plaza North ACCREDITED NVLAP Lab .Code # 1187 Long Island City, NY 11101 Report Date: 10/23/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register-(40 CFR, Part 763), Vol. 52,’ No. 210, October 30, 1987
Sarr.ple Identification Analysis Parameters
Project/Site: New Stuyvesant H.S., 34 5 Chambers St., NY, NY TEM Sample No.: 5739 - 61946 Exterior & Interior of Building & Roof Date Received: 12/22/^ Grid Openings Analyzed:__ 4
Project Sample No.: 11 Average Grid Opening: 106.00 urn
A.lr Volume: 1944 liters Total Area Analyzed: 0.0450 tnm2
Filter Typ e : Analytical Sensitivity:22^.^,,s/nTm2 Effective Area: 3^5 mm2 0.0044 s/cc
FIBROUS P7\RTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >°5um Struct/mm2 Struct/cc ngm/m3
Cnrysotile Asbestos 0 0 0 0 0 0 0.0- 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 o.opoo 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 . Non-Asbestos 0 0 0 0 0 0 0.0 0.0000’ N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS./SAED) : None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the, quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003099711
NYC-WTC_000270713
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000293768
TEM-based asbestos analysis with SAED/EDS for exterior/interior of building.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293774
TEM analysis with SAED/EDS for New Stuyvesant HS exterior/interior, received 10/21/01.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270797
TEM asbestos fiber analysis for New Stuyvesant H.S. exterior and interior areas.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293818
TEM with SAED/EDS identification for New Stuyvesant High School exterior/interior areas, Received 10/22/01.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293904
TEM analysis parameters; exterior/interior, 1944 liters air volume.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293816
TEM analysis with SAED/EDS, New Stuyvesant H.S., Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293901
TEM data with air volume and analysis parameters for building sample.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293809
Asbestos TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293423
Asbestos TEM analysis, exterior/interior of building, 10/09/01.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293771
TEM analysis including opening, air volume and 0.0450 mm2 area details.
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270677
TEM analysis of asbestos fibers; SAED/EDS identification, New Stuyvesant H.S., Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188647
TEM analysis report for asbestos fibers collected from the exterior and interior of a high school building in October 2001.
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000293768
TEM-based asbestos analysis with SAED/EDS for exterior/interior of building.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293774
TEM analysis with SAED/EDS for New Stuyvesant HS exterior/interior, received 10/21/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270797
TEM asbestos fiber analysis for New Stuyvesant H.S. exterior and interior areas.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293818
TEM with SAED/EDS identification for New Stuyvesant High School exterior/interior areas, Received 10/22/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293904
TEM analysis parameters; exterior/interior, 1944 liters air volume.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293816
TEM analysis with SAED/EDS, New Stuyvesant H.S., Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM-based asbestos analysis with SAED/EDS for exterior/interior of building.
Similar indexed content
TEM analysis with SAED/EDS for New Stuyvesant HS exterior/interior, received 10/21/01.
Similar indexed content
NYC-WTC_000270797
TEM asbestos fiber analysis for New Stuyvesant H.S. exterior and interior areas.
Similar indexed content
TEM with SAED/EDS identification for New Stuyvesant High School exterior/interior areas, Received 10/22/01.
Similar indexed content
TEM analysis parameters; exterior/interior, 1944 liters air volume.
Similar indexed content