ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board,of'Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/22/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method:- AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification ftnalysis Parameters

Project/Site: New Stuyvesant H.S'., 345 Chambers St., NY, NY TEM Sample No.: 5737 - 61831 Exterior & Interior of Building & Roof Date Received: 10/21/01 Grid Openings Analyzed:__ 4

Project Sample No.: 10 Average Grid Opening: 106.00 urn

Air Volume :192enters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam. Pore Size: 0.4S urn Analytical Sensitivity:^2^.2 s/mm2 Effective Area; 385 mm2 Q.Q044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5uni Struct/mTn2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 1 1 0 22.2 0.0044 147

Amphibole Asbestos 0 0 0 0 0 0 • 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 1 0 22.2 0.0044 147 Non-Asbestos 0 0 0 0 0 0 0.0 0.(3000 N/A No Identification 0 0 0 0 0 6 0.0 0.0000 N/A

Totals (All Structures) 1 0 22.2 0.0044 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with, the quality specified for the method.

Tinalyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_0 03099663

NYC-WTC_000270671

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270671Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000294022

TEM-based asbestos identification and SAED/EDS for exterior & interior samples at New Stuyvesant H.S.

Similar indexed content

NYC-WTC_000270549

TEM asbestos analysis for New Stuyvesant H.S.; SAED/EDS methods; includes date.

Similar indexed content

NYC-WTC_000293867

TEM asbestos analysis; exterior/interior details; received 10/23/01; opening and area measurements listed.

Similar indexed content

NYC-WTC_000292755

TEM data: air volume, opening, and diffractive measurements for New Stuyvesant H.S., 10/28/01.

Similar indexed content

NYC-WTC_000293897

TEM and SAED/EDS analysis for exterior/interior of building; sample 5758.

Similar indexed content

Compare copies and versions →