NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 28%

Asbestos fiber TEM analysis report for New Stuyvesant High School, identifying fibers with SAED/EDS.

NYC-WTC_000270666
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/22/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY' (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuwesant H.S.-, 345 Chambers St., NY, NY TEM Sample No.: 5737 - 61B26 . Exterior & Interior of Building a Roof Date Received; 10/21/^ Grid Openings Analyzed:__ 4

Project Sample No.: 5 Average Grid Opening: 106.00 uir.

Air Volume: 1928 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity; 22.2 s/mm? Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter ■Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nam/m3

Chrysotile Asbestos 0 0 0 0 0 0 0,0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 . 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method'. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_0 03099658

NYC-WTC_000270666

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270666Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270927

TEM asbestos analysis for New Stuyvesant High School, Oct 2001.

Similar indexed content

Asbestos air sampling results, NYC DOE site, Oct 2001

NYC-WTC_000188712

Laboratory report detailing asbestos fiber analysis by transmission electron microscopy for air samples collected at a New York City Department of Education site in October 2001.

Similar indexed content

NYC-WTC_000293864

TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.

Similar indexed content

NYC-WTC_000270753

TEM analysis report for New Stuyvesant High School building exterior and interior, 10/24/01.

Similar indexed content

NYC-WTC_000270929

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →