ATC .Environmental, Inc. 104 East 25th Street New York, New York 10010 '

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (4D CFR, Part 763), Vol. 52, No. 210, October 30, 19S7

Sample Identification AnalysisParaniet^^

Project/Site; New SLuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5725 - 61654 Exterior & Interior of Building &. Roof Date Received; 10/18/01 Grid Openings Analyzed: 4

Project Sample No.;_^ Average Grid Opening: 106.00 urn

Air Volume: 1920 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity:22;2 s/mra2 Effective Area: 385 mm2 0. Q045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >e5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous’ structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Tinalyzed by; Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099530

NYC-WTC_000270555

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270555Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293500

TEM asbestos analysis for exterior/interior samples; New Stuyvesant High School; received 10/13/01.

Similar indexed content

NYC-WTC_000270759

TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.

Similar indexed content

NYC-WTC_000270545

TEM asbestos analysis with AHERA method for New Stuyvesant H.S.; lists sample numbers and date.

Similar indexed content

NYC-WTC_000293864

TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.

Similar indexed content

Compare copies and versions →