ATC Environmental, Inc. 104 East 25th Street New York, New -York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island. City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA'Federal Register (40 CFR, Part 76S), Vol, 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site; New Stuyvesant H.S., 345 Chambers Sth NY, NY TEM Sample No.: 5725 - 61647 Exterior Interior of Building & Roof Date Received: 10/18/01 Grid Openings Analyzed;__ 4

Project Sample No.: 15 Average Grid Opening: 106.0'0 urn

Air Volume; 1920 liters Total Area Analyzed 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity;22;2 s/mn^ Effective Area: 385 rnrri2 O.004S s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix 'Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/'mm2 Struct/cc ngm/ni3

Chrysotile Asbestos 0 0 0 1 1 0 22.2 0.0045 14 7

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

•Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 1 0 22.2 0.0045 147 Non-Asbestos 0 0 0 0 0 0 -0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 1 0 22.2 0.0045 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TSM method. ■ This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099523

NYC-WTC_000270548

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270548Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270883

TEM analysis; exterior & interior, sample 16.

Similar indexed content

NYC-WTC_000270919

TEM analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293820

TEM analysis of exterior/interior building samples; SAED/EDS; Received 10/22/01.

Similar indexed content

NYC-WTC_000270552

TEM asbestos analysis with SAED for New Stuyvesant H.S.; includes sample numbers and date.

Similar indexed content

Compare copies and versions →