NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/16/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR. Part 763), Vol. 52. No. 210. October 30, 1987
Sample Identification AnalysisParaniece^
Project/Sit€: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5709 61444
Exterior & Interior of Building & Roof
Date Received; 10/16/01 Grid Openings Analyzed:__ 4
Project Sample No.: NSH5>EIR»10/16-ll Average Grid Opening: 106.QO urn
A.Lr Volume: 1899 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm diam. Pore Size: 0.45 urn Analytical Sensitivity:22.;^s/mm2
Effective Area: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >-5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
AjTibiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0..0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 ' 0.0 0.0000 N/A
Totals '(All Structures) 0 0 0.0 0.oooo N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried,out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki,.Ph.D.
Director of Electron Microscopy
CITY_21MC100_003099461
NYC-WTC_000270492
OCR can misread numbers and units. Confirm readings against the page image before using them.