Asbestos TEM analysis for New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 45%

Asbestos fiber analysis by TEM for exterior and interior surfaces at New Stuyvesant High School, sample received Oct 15, 2001.

NYC-WTC_000270466
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N-, Y. State ELAP #10879 28-11 (2ueens Plaza North ACCREDITED NVLAP Lab Code #,1187 Long Island City, NY 11101 Report Date: 10/16/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule,. EPA Federal Register (40 CFR, Part 763) , Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Sibe: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. :5£98^61344 Exterior & Interior of Building & Roof Date Received: 10/15/01 Grid Openings Analyzed:__ 4

Project Sample No.: NSHS-EIR-IO/15-11 Average Grid Opening: 106.00 urn

Air Volume: 1908 libers Total Area Analyzed: 0.0450 mm2

Filter Typ.e: MCE 25 mm diam. , Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area: 38^mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single . Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ncrm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000. N/A No Identification 0 0 . 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the'approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099433

NYC-WTC_000270466

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270466Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM air analysis report, Oct 16 2001

NYC-WTC_000182556

Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 16, 2001.

Similar indexed content

NYC-WTC_000270517

TEM analysis of exterior/interior samples from New Stuyvesant High School, received 10/17/01.

Similar indexed content

Compare copies and versions →