NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, NSHS 61340, Oct 2001

Machine-extracted title · confidence 24%

TEM analysis of NSHS exterior/interior sample 61340, received 10/15/01.

NYC-WTC_000270463
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 ■ 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/16/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1967

Sample Identification Ana^ArsisParanieters

Project/Site; Hew Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5698 - 61340 Exterior & Interior of Building £ Roof Date Received: 10/15/01 Grid Openings Analyzed:__4

Project Sample No. NSHS-ElR-10/15-07 Average Grid Opening-. 106.00 urn

Air Volume: 1899 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MC3 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mni2 Effective Area: 385 mm2 0■0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total.. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5uni Struct/mni2 Struct/cc nam/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0,

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 , 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 - 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Ttnalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed•by: Report Reviewed by:

Marek PSysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099429

NYC-WTC_000270463

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270463Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270916

TEM-based asbestos fiber analysis for New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000270977

TEM-based asbestos fiber analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.

Similar indexed content

NYC-WTC_000293522

TEM analysis of exterior/interior of NSHS building, Oct 2001.

Similar indexed content

NYC-WTC_000270432

TEM analysis identifying asbestos via SAED/EDS for exterior and interior samples from New Stuyvesant High School, received 10/15/01.

Similar indexed content

Compare copies and versions →