NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis report, lab sample 61080, Oct 2001

Machine-extracted title · confidence 42%

TEM analysis of air sample from New Stuyvesant H.S. exterior/interior, Oct 2001.

NYC-WTC_000270452
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP #: 5691 - 10/15/01 Lab Sample No. 61080 Filter T/pe MCE 25 mm opera cor. Client Spl. No. NSHS-EIR-10/14-12 Filter Area 365 mm"2 Inscrumenc I.D. EMIOC^ Grid I.D. Disk No. Screen Magnification 16,40OX (GO) Area Q.01124 Comments. Acc. Voltage 80 kV No. GO to be Analyzed ( 3.147 Struct. Corspd. to 70 5/rim"2.)

GO. Structure Structure Type Length I.D. of Structure EDS >0.5 urn (Nonasb. No, Coord. No. F B C M > Sum Chrys. Amphibole Nonasb. Ambig./ND Elements) < 5 um

ESS

Store all unrepeated spectra—^ Photo No. (from 1 in S asbcstoa— Identify all structures using EDS Check diffraction for asbestos containing samples) Grid acceptance:! structures up to 70e/&n <l»l 4) <50% undiasolvea niter, overlappe<f or folded Struck = > O.Sum & > 5:1 Aspect Ratio <10X particulate coverage >S0X coverage Totals Ns Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares Positive diffraction pattara properties conforming <SX holes or opaoue areas F B C M > Sum to laboratory identification criteria observed. 'Unused porUon Por ehrysoUlai Q.Tanm anaelni for (020) renacUona, of niter Chrysotile O.SOniB apaelnc fo^ Iha layer line repeat, atreaking -Avoided porUon of (110) and (130) refloQUona. er filter Por amphiboles: O.Unm layer Une repeat, and approx. Portion of niter (Emm wide) 3.8 ratio of nan-twinned layer Une spot spacing to ■ubjact to Amphibole layer line repeat diitanca (O.Sanm). examioaUon

EDS spectrum conforming to laboratory Ambiguous Identification critarta observed. AMPHIBOLES P= Single Fiber (1-3 InLeraccUona = 1-3 fibers) Amosile Bs Bundle {>3 fibers <1 fiber diameter apart) SSmm fitter Crocidolite Non-asbestos C= Cluster (>3 IntenecUoni) I--------- 1 Stoppini Rulas; I------- U= Matrix Anthophyllite NSD= No Structures Detected >ao b/C,O. or Id lat 4 C.O. Tremolite Actinolite Non-Identified L:\DATA\PWVATr\MlKEC\CAQD'^X«3 «/22/M

CITY_21MC100_003099418

NYC-WTC_000270452

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270452Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM analysis, NSHS, Oct 2001

NYC-WTC_000270338

TEM analysis report; structure imaging and EDS data for NSHS samples, 10/01.

Similar indexed content

Compare copies and versions →