Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 40%

TEM analysis including EAED/EDS for interior of New Stuyvesant High School, received 10/15/01.

NYC-WTC_000270436
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/15/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction (EAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987.'^

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5691 - 61076 Exterior St Interior of Building & Roof Date Received: 10/15/01 Grid Openings Analyzed:__ 4

Project Sample No.: NSHS-EIR-lQ/14-06 Average Grid Opening; 106.00 urn

Air Volume: 1890 liters Total Area Analyzed-. 0.04 50 mm2-

Filter Type: MCE 25 tnm diam. Pore Size: 0.45 um Analytical' Sensitivity: 22.2 s/iinn2 Effective Area: 365 mm2 0,0045 S/CC

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ncim/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed-by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO3O994O2

NYC-WTC_000270436

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270436Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293618

TEM asbestos analysis for New Stuyvesant HS exterior/interior areas, received 10/17/01.

Similar indexed content

NYC-WTC_000270515

TEM asbestos fiber analysis results for New Stuyvesant High School samples, received 10/17/01.

Similar indexed content

TEM air analysis report, Oct 23 2001

NYC-WTC_000182586

Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 23, 2001.

Similar indexed content

Compare copies and versions →