NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 40%

TEM analysis with SAED/EDS; exterior/interior building areas; 10/14/01.

NYC-WTC_000270407
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code #1187 ' Long Island City, NY 11101 Report Date: 10/14/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification AnalysisPararnet^rs

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5667 - 61059 Exterior & interior of Building & Roof Date Received: 10/14/01 Grid Openings .Analyzed:__ 4

Project Sample No.: NSHS-EiR-10/13-06 ■ Average Grid Opening: 106.00 um

Air Volume: 1899 liters Total Area Analyzed: 0.0450 mtn2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity:22;2 s/mm2 Effective Area-. 385 mr^ 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Humber Observed CONCENTRATION Total Single Matrix Total. Struct. 'Filter Air Fibers Bundles Clusters Struct. Struct >eSum Struct/mm2 Struct/cc nain/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

• Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous' structures) 0 0 0.0 0.0000 0 ■

Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 ' 0 0.0 0.0000 N/A

Totals (All Structures) O' 0 0.0 0.0000 N/A - The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Analysis was carried- out in accordance with the approved TEM method.. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_002571877

NYC-WTC_000270407

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270407Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000292750

TEM analysis parameters for exterior/interior of building at New Stuyvesant H.S., 10/28/01.

Similar indexed content

NYC-WTC_000270430

Asbestos fiber analysis by TEM with SAED/EDS on New Stuyvesant High School exterior/interior samples, received 10/15/01.

Similar indexed content

NYC-WTC_000293936

TEM analysis results for air samples at New Stuyvesant HS, exterior/interior, 10/25/01.

Similar indexed content

NYC-WTC_000244515

TEM analysis with SAED/EDS for New Stuyvesant H.S. exterior/interior, Oct 2001.

Similar indexed content

TEM air analysis report, Oct 16 2001

NYC-WTC_000182556

Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 16, 2001.

Similar indexed content

Compare copies and versions →