NYC-WTC_000294017
TEM analysis of exterior/interior air at New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM analysis of NSHS samples; exterior/interior; 10/14/01.
NYC-WTC_000270405OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
■N.Y.C. Board of Education Approved N.Y, State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/14/01
ASBESTOS- FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part_763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuyvesant H.S., '345 Chambers St., NY, NY TEM Sample No.: 5687 - 61057 Exterior &. interior of Building &. Roof Date Received: 10/14/01 Grid Openings Tinalyzed:__ 4
Project Sample No. .■ MSHS-EIR-10/13-04 Average Grid Opening: IOS.00 um
Air Volume: 1917 liters Total Area Analyzed: 0.0450 mni2
Filter Type; MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mni2 Effective Area: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES /ANALYZED Number Qbsei-ved CONCENTRATION Total Single Matrix Total. Struct. Filter . Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 'Struct/cc nqin/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 1 1 22.2 0.0045 147
Ambiguous 0 0 0 0 0 0 0.0 . 0.0000 0
Total asbestos {includes ambiguous structures) 1 22.2 0.0045 147 Non-Asbestos 0 0 0 0 0 0 0.0 0,0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 ■N/A
Totals (All Structures) 1 1 22.2 0.0045 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_002571875
NYC-WTC_000270405
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000294017
TEM analysis of exterior/interior air at New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270377
TEM asbestos analysis report for New Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293897
TEM and SAED/EDS analysis for exterior/interior of building; sample 5758.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188685
Laboratory report documenting transmission electron microscopy results for asbestos fibers collected at a high school site.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270484
TEM analysis with SAED/EDS for exterior/interior of New Stuyvesant HS; AHERA method.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270810
TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188482
Laboratory report detailing asbestos fiber analysis by TEM and EDS for exterior and interior building samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270969
TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292755
TEM data: air volume, opening, and diffractive measurements for New Stuyvesant H.S., 10/28/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292747
Asbestos TEM analysis for exterior/interior of New Stuyvesant H.S., Oct 28–29, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270980
TEM asbestos analysis for exterior/interior of New Stuyvesant High School, received 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188705
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294017
TEM analysis of exterior/interior air at New Stuyvesant H.S., Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270377
TEM asbestos analysis report for New Stuyvesant High School, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293897
TEM and SAED/EDS analysis for exterior/interior of building; sample 5758.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270384
TEM asbestos analysis report for exterior/interior of building, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188685
Laboratory report documenting transmission electron microscopy results for asbestos fibers collected at a high school site.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270484
TEM analysis with SAED/EDS for exterior/interior of New Stuyvesant HS; AHERA method.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis of exterior/interior air at New Stuyvesant H.S., Oct 2001.
Similar indexed content
TEM asbestos analysis report for New Stuyvesant High School, Oct 2001.
Similar indexed content
TEM and SAED/EDS analysis for exterior/interior of building; sample 5758.
Similar indexed content
NYC-WTC_000188685
Laboratory report documenting transmission electron microscopy results for asbestos fibers collected at a high school site.
Similar indexed content
TEM analysis with SAED/EDS for exterior/interior of New Stuyvesant HS; AHERA method.
Similar indexed content