NYC-WTC_000270309
TEM asbestos analysis for New Stuyvesant HS exterior & interior, received 10/09/01.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis for NSHS exterior/interior, Oct 2001.
NYC-WTC_000270362OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education .Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED.NVLAP Lab Code'# 1187 Long Island City, NY 11101 Report Date: 10/12/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Idencification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Samole Identification AnaJ^/sisParameters
Project/Site: New Stuvvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5668 - 6093.9 Exterior a Interior of Building & Roof Date Received: 10/11/01 Grid Openings Analyzed; 4
Project Sample No.: NSHS-EIR-10/11-12 Average Grid Opening: 106.00 um
Air Volume: 1917 liters Total Area Analyzed: 0.0450 mtn2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385mn^ 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 - 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 ' 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.oooo 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003099350
NYC-WTC_000270362
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270309
TEM asbestos analysis for New Stuyvesant HS exterior & interior, received 10/09/01.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293593
TEM analysis results for exterior interior of building; opening and area data.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270759
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293470
TEM analysis of exterior/interior building for NSHS-EIR-10/11-02.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293367
TEM analysis of exterior and roof for Stuyvesant High School; 10/06/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293518
TEM-based asbestos fiber analysis for New Stuyvesant High School site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293477
TEM asbestos identification and diffraction/EDS on samples from New Stuyvesant High School.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293500
TEM asbestos analysis for exterior/interior samples; New Stuyvesant High School; received 10/13/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188634
Laboratory report detailing transmission electron microscopy analysis of air samples collected from a New York City high school site.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270304
TEM asbestos analysis with SAED/EDS for New Stuyvesant High School exterior/interior, received 10/09/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270354
TEM asbestos analysis involving SAED/EDS, NSHS site, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270359
TEM asbestos analysis on NSHS sample 10/11-09, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270309
TEM asbestos analysis for New Stuyvesant HS exterior & interior, received 10/09/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293593
TEM analysis results for exterior interior of building; opening and area data.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270759
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293470
TEM analysis of exterior/interior building for NSHS-EIR-10/11-02.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293367
TEM analysis of exterior and roof for Stuyvesant High School; 10/06/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293518
TEM-based asbestos fiber analysis for New Stuyvesant High School site, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000270309
TEM asbestos analysis for New Stuyvesant HS exterior & interior, received 10/09/01.
Similar indexed content
TEM analysis results for exterior interior of building; opening and area data.
Similar indexed content
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
Similar indexed content
NYC-WTC_000293470
TEM analysis of exterior/interior building for NSHS-EIR-10/11-02.
Similar indexed content
NYC-WTC_000293367
TEM analysis of exterior and roof for Stuyvesant High School; 10/06/01.
Similar indexed content