TEM analysis, NSHS exterior/interior, Oct 2001

Machine-extracted title · confidence 27%

TEM analysis with 0.45 µm diffraction data for NSHS exterior/interior, Oct 2001.

NYC-WTC_000270358
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y, State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/12/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEN) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5668 - 60935 Exterior & Interior of Building & Roof Date Received: lO/ljTol Grid Openings Analyzed:__4

Project Sample No.: NSH5-EIR-10/11-O8 Average Grid Opening: 106.00 um

Air Volume: 1899 liters Total Area Analyzed: 0.0450 mrn2

Filter Typ e: MCE 25 nun diam., Pore Size: 0.45 um Analytical Sensitivity:22;2 s/mrn2 Effective Area: 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES TU^ALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct.. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A . The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099346

NYC-WTC_000270358

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270358Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293428

Asbestos TEM analysis, exterior/interior, 10/09/01.

Similar indexed content

NYC-WTC_000270593

TEM-based asbestos analysis with SAED/EDS for air samples at New Stuyvesant High School.

Similar indexed content

NYC-WTC_000293419

Asbestos TEM analysis for exterior/interior of building at New Stuyvesant HS, 10/09/01.

Similar indexed content

Compare copies and versions →