Asbestos TEM analysis, NSHS 10/11-07, Oct 2001

Machine-extracted title · confidence 28%

TEM asbestos analysis of NSHS sample NSHS-EIR-10/11-07, exterior/interior, Oct 2001.

NYC-WTC_000270357
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N,Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/12/01 .

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1907

Sample Identificacion Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. ;5668:^0934 Exterior & Interior of Building & Roof' Date Received:1O/1VO1 Grid Openings Analyzed:__ 4

Project Sample No.: HSHS-EIR-10/11-07 Average Grid Opening: 106.00 urn

Air Volume: 1917 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size; 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area: 365 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 . 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099345

NYC-WTC_000270357

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270357Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270760

TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.

Similar indexed content

NYC-WTC_000270432

TEM analysis identifying asbestos via SAED/EDS for exterior and interior samples from New Stuyvesant High School, received 10/15/01.

Similar indexed content

TEM air analysis report, Oct 16 2001

NYC-WTC_000182556

Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 16, 2001.

Similar indexed content

Compare copies and versions →