ATC Environmental, Inc. 104 East- 25th Street New York, New York 10010

N.Y.C. Board of Education Approve.d N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/10/01'

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON’MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5662 - 60800 Exterior & Interior of Building a Roof Date Received: 10/10/01 Grid Openings Analyzed:__ 4

Project Sample No.: HSHS-EIR-10/lD-01 Average Grid Opening: 106.00 urn

Air Volume: 1890 liters Total Area Analyzed: 0.0450 mmZ

Filter Type: MCE 25 mm diam.. Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Scruct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 • 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 ■ 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty'of’ this analysis is 1 standard .deviation.

Nori-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO3O99311

NYC-WTC_000270325

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270325Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270304

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School exterior/interior, received 10/09/01.

Similar indexed content

NYC-WTC_000293384

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S. exterior site, received 10/07/01.

Similar indexed content

NYC-WTC_000293864

TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.

Similar indexed content

NYC-WTC_000270666

Asbestos fiber TEM analysis report for New Stuyvesant High School, identifying fibers with SAED/EDS.

Similar indexed content

Compare copies and versions →