NYC-WTC_000293384
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S. exterior site, received 10/07/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis with SAED/EDS for New Stuyvesant High School exterior/interior, received 10/09/01.
NYC-WTC_000270304OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/09/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber .Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register. (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5649 - 60680 Exterior k Interior of Building & Roof 'Date Received: 10/09/01 Grid Openings Analyzed:__ 4
Project Sample No.: NSHS-EIR-10/9-03 Average Grid Opening: 106.00 utr
Air Volume: 1906 liters Total Area TPaalvzed: 0.0450 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um TUialytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm2 0.004S s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total single Matrix Total. ' Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mni2 Struct/cc nQm/rn3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 .0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbe'stos 0 0 , 0 0 0 0 0.0, 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The. estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance■with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC1OO_OO3O99285
NYC-WTC_000270304
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000293384
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S. exterior site, received 10/07/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270706
TEM analysis and diffraction/EDS data for exterior & interior of New Stuyvesant HS.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293367
TEM analysis of exterior and roof for Stuyvesant High School; 10/06/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293621
TEM asbestos fiber analysis of exterior and interior building samples from New Stuyvesant High School, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270309
TEM asbestos analysis for New Stuyvesant HS exterior & interior, received 10/09/01.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188712
Laboratory report detailing asbestos fiber analysis by transmission electron microscopy for air samples collected at a New York City Department of Education site in October 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270929
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270678
TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270753
TEM analysis report for New Stuyvesant High School building exterior and interior, 10/24/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270354
TEM asbestos analysis involving SAED/EDS, NSHS site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270927
TEM asbestos analysis for New Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293518
TEM-based asbestos fiber analysis for New Stuyvesant High School site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000293384
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S. exterior site, received 10/07/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270706
TEM analysis and diffraction/EDS data for exterior & interior of New Stuyvesant HS.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293367
TEM analysis of exterior and roof for Stuyvesant High School; 10/06/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293621
TEM asbestos fiber analysis of exterior and interior building samples from New Stuyvesant High School, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270309
TEM asbestos analysis for New Stuyvesant HS exterior & interior, received 10/09/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188712
Laboratory report detailing asbestos fiber analysis by transmission electron microscopy for air samples collected at a New York City Department of Education site in October 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S. exterior site, received 10/07/01.
Similar indexed content
TEM analysis and diffraction/EDS data for exterior & interior of New Stuyvesant HS.
Similar indexed content
NYC-WTC_000293367
TEM analysis of exterior and roof for Stuyvesant High School; 10/06/01.
Similar indexed content
TEM asbestos fiber analysis of exterior and interior building samples from New Stuyvesant High School, Oct 2001.
Similar indexed content
NYC-WTC_000270309
TEM asbestos analysis for New Stuyvesant HS exterior & interior, received 10/09/01.
Similar indexed content