NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, Stuy HS site, Oct 2001

Machine-extracted title · confidence 42%

TEM analysis of Stuyvesant HS site samples, Oct 2001.

NYC-WTC_000270276
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC'Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/07/01.

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 2io', October 30, 1967

Sample Identification Analysis Parameters

Project/Site: New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5629 - 6D359 Exterior of Building & Roof Date Received :10/07/M Grid Openings Analyzed:__ 4

Project Sample No.: NSHS-EBR-10/7-05 Average Grid Opening: 106.00 urn

Air Volume: 1890 liters Total Area Analyzed: 0.04S0 mm2

Filter Type: MCS 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area :385 rniT^ 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >e5um Struct/mni2 Struct/cc nQm/na3

■Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos ■ 0 0 0 0 0 0 . 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 ' 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 D Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 '0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber.i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by:- Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099251

NYC-WTC_000270276

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270276Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293384

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S. exterior site, received 10/07/01.

Similar indexed content

NYC-WTC_000270304

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School exterior/interior, received 10/09/01.

Similar indexed content

NYC-WTC_000188628

Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.

Similar indexed content

Asbestos air sampling results, NYC DOE site, Oct 2001

NYC-WTC_000188712

Laboratory report detailing asbestos fiber analysis by transmission electron microscopy for air samples collected at a New York City Department of Education site in October 2001.

Similar indexed content

NYC-WTC_000270927

TEM asbestos analysis for New Stuyvesant High School, Oct 2001.

Similar indexed content

Compare copies and versions →