NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/07/01

ASBESTOS FIBER TkNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, Ko. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site; New Seuwesant U.S., 345 Chambers St., NY, NY TEM Sample No.: 5629 - 60355 Exterior of Building & Roof Date Received: 10/07/01 Grid Openings Analyzed;__4

Project Sample No.: KSHS-EBR-10/7-01 Average Grid Opening: 106.00 urn

Air Volume; 1890 liters Total Area Analyzed: 0.0450 niin2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity; 22.2 s/fnm2 Effective Area; 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANT^YZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5uin Struct/mm2 Struct/cc nom/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099247

NYC-WTC_000270273

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270273Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293860

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000270815

TEM asbestos analysis, exterior/interior of building, New Stuyvesant HS.

Similar indexed content

NYC-WTC_000270379

TEM asbestos analysis report for exterior/interior of building, Oct 2001.

Similar indexed content

NYC-WTC_000293689

TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS data.

Similar indexed content

Compare copies and versions →