TEM analysis, NSHS sample 60249, Oct 2001

Machine-extracted title · confidence 42%

TEM analysis with EDS for NSHS sample 60249, Oct 2001.

NYC-WTC_000270267
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP ff: 5623 - 10/06/01 Lab Sample No. 60249 Filter Type MCE 25 mm Operator Client Spl. No. NSHS-EBR-10/6-05 Filter Area 385 mm'^2 Instrument I.D. EM 10 CRX Grid I.D. Disk No. Screen Magnification 16,400X (GO) Area 0.01124 nini-2 Comments Acc. Voltage 80 kV No. GO to be Analyzed 4 ( 3.147 Struct. Corspd. to 70

GO. structure Structure Type Length I.D. of Structure N or EDS ^0.5 um (Nonasb. No Coord. No. F B C M Sum Chrys. Amphibole Nonasb. Ambig./ND Elements) < 5 um

<3 O

Store all unrepeated spectra-^ — Photo No. (from 1 In 5 asbestos— Identify all atructurea uaing EDS Chee c diffraction for aabeatoa containing aamples) Grid accepLanee:! structurea up to TOa/^m- (Iat 4) <50% undiasoived filter, overlapped or folded Struck s > O.Sum A > 5:1 Aspect Ratio <10X particulate coverage >5OX coverage Totals Ns Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares y/- Positive diffraction pattern properties conforming <SX holes or opaque areas 'F B C M > Sum

r to laboratory idenUflcatlon criteria observed. ■UnuBod portion of niter Por ehrysetJlei 0.73am ssaclnc (er (020) rwflseUana, 0.&3ntn spacing for the layer line-repeat^ streaking Chrysotile -Avoided portion or (110) and (130) reneeUoas. of niter Por amphiboles: O.a3nm layer line repeat, and approx. I Portion of filter (2mm wide) 3.a ratio of non-lwlnned layer Une ipoL apaeing to I subject to BxsmlnaUon Amphibole layer Une repeat distance (O.&Snm). v/= EDS spectrum conforming to laboratory Ambiguous identification criteria observed. AMPHIBOLES F= SinilB Fiber (1-3 IntnnenUoni = 1-3 ribera) Amosite Bs Bundle (>3 flben <1 fiber diameter apart) 2Smm filler Crocidolite Non-asbestos Cs Cluster (>3 intersections) Jstnppini Rules: Anthophyllite Ms Matrli NSDs No Structurea Detected U\DATA\PRlVATC\MtKBC\CADDVEUS I >30 i/C.O. or In l«l 4 C.O. B/22/SB Tremolite Actinolite Non-Identified

CITY_21MC100_003099240

NYC-WTC_000270267

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270267Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270471

TEM analysis of lab sample from New Stuyvesant HS exterior/interior, Oct 2001, under AHERA methods.

Similar indexed content

Compare copies and versions →