NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant H.S., 09/2001

Machine-extracted title · confidence 42%

TEM asbestos analysis report including SAED/EDS for New Stuyvesant High School.

NYC-WTC_000270222
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

New York City Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code- # 118 7 Long Island City, NY 11101 Report Date: 09/21/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) Mich Fiber Identification by Selected-Area Electron Diffraction ISAED) and Energy-Dispersive X-RAY Spectroscopy lEDSl Method: AHERA Final Rule, ERA Federal Register (40 CFR, Part 7G3), Vol. 52, No. 210, October 30, 1987

Sample Iderxificacion •Analysis Parameters

Project/Site; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. :_554^^__^9^ 11th Floor Mechanical Space Date Received: 09/21/01 Grid Openings Analyzed: 4

Project Sample No.: NSHS-llMS-9/21-14 Average Grid' Opening: 106,00 urn

Air Volume: 1820 liters •Total Area Analyzed; 0.0450 mm2

Filter Type: MC5 25- mm diam., Pore Size: 0.45 urn Analytical Sensitivity:• 22.2 s/mm2 Effective Area; 385 nvn2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION. Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ■ssRnm Struct/[nm2 SCruct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos {includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 o '. 0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0,0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.'

Non-asbestos fiber i.d. (EDS/SAED) None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099187

NYC-WTC_000270222

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270222Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293320

TEM asbestos fiber analysis for New Stuyvesant High School, received 09/21/01.

Similar indexed content

NYC-WTC_000293309

TEM asbestos fiber analysis for New Stuyvesant High School, received 09/21/01.

Similar indexed content

NYC-WTC_000270436

TEM analysis including EAED/EDS for interior of New Stuyvesant High School, received 10/15/01.

Similar indexed content

Compare copies and versions →