NYC-WTC_000270778
TEM analysis details for lab sample 62062, instrument and area data.
7 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗TEM analysis of sample 60059 with instrument, area, voltage and structure IDs.
NYC-WTC_000270173OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP ft-. 5609 - 10/05/01 Lab Sample No. 60059 Filter Type MCE 25 mm Operator Client £pl. No. SKS-l>10-10/5-52 Filter Area 335 mm"2 Inscrutnenc I. D. EM 10 CRX Grid I.D. Disk No. Screen Magnification .16,4QQK (GO) Area 0.01124 mm"2 Commen.c.3 Acc. Voltage 80 kV No. GO to be Analysed 4 ' ( 3.147 Struct. Corspd. to 7Q s/inm^2.)
GO. Structure structure Type Length I.D. of Structure EDS ^0.5 um (Nonasb. No Coord. No. F B C M Sum Chrya. Amphibole Nonaab. Ambig./ND Elements) < 5 um /
Sx i/ II
■ Photo No. (from 1 in 5 aabeatoa- Identify , ail atructurea using KPS1 Check diffraction for aabeatoa Store all unrepeated spectra conLaining samples) Grid acceptance:! atructurea up to TOa/Am (lai 4) <S0X undisaolved hiter. overlapped or foidea Struct. = > O.Sum & > 5:1 Aspect Ratio <10X parUcuiate coverage >60X coverage Totals N= Not Okeerred (EDS apectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares Positive diffraction pattern properties conformlnf <SX holes or opaque areas F B C M > 5um to laboratory identification criteria observed. 'Unused portion of niter For ehrysoUlas Q.73nm spacine for (020) raflecUons, O.aanm ipacing for the layer line repeal, itreaklng -Avoided portion Chrysotile of (110) and 030) reflecUons. of niter For amphibotea: 0.33nni layer line repeat, and approx. (2mm wide) 3.S ratio of noa-twtnned layer Una spot spacing to Amphibole layer Une repeat distance (Q.Mnm). v/s SOS spectrum eonformlnt to laboratory idenUficatton criteria observed. AMPHIBOLES Ambiguous F= Single Fiber (1-3 Interaectlona - 1-3 fibers) Amosite Ba Bundle (>3 fibers <1 fiber diameter apart) Cs Cluater (>3 interaecUanal 29min nitar Crocidolite Non-asbestos stopping Rules: I--------- - Anthophyllite Ms Matrix NSDs No Struciurca Detected >00 s/C.O. or In 1st 4 G.O. Tremolite Actinolite Non-Identified Lj\DATA\PWVATB\MlKKC\CAOO\rEM3 8/22/08
CITY_21MC100_003099123
NYC-WTC_000270173
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270778
TEM analysis details for lab sample 62062, instrument and area data.
7 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270613
TEM analysis parameters and structure identifications; EDS notes included.
7 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270370
TEM analysis of samples, 25 mm filter, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293361
TEM analysis header with sample and structure IDs for 10/04/01.
7 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270451
TEM analysis of air sample for NSHS-SIR-10/H site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293392
TEM analysis record with structure IDs and EDS data for asbestos, 10/07/01.
7 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270136
TEM analysis for Stuyvesant High School samples; identifies structures via EDS.
7 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294091
TEM analysis record for 60025; SHS-1>10-10/5-13, structure and EDS data.
6 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270153
TEM analysis data, structure identification and EDS notes for a Dept. of Education sample.
7 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237312
Detailed transmission electron microscopy data sheet recording structural identification and measurements for air samples from 40 Rector Street.
7 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000365427
TEM analysis results for sample 62217 with microscopy details and structure IDs.
7 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000365520
TEM analysis results with structure IDs and EDS information for sample 62177.
7 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270778
TEM analysis details for lab sample 62062, instrument and area data.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270613
TEM analysis parameters and structure identifications; EDS notes included.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270370
TEM analysis of samples, 25 mm filter, Oct 2001.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293361
TEM analysis header with sample and structure IDs for 10/04/01.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237312
Detailed transmission electron microscopy data sheet recording structural identification and measurements for air samples from 40 Rector Street.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270451
TEM analysis of air sample for NSHS-SIR-10/H site, Oct 2001.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000270778
TEM analysis details for lab sample 62062, instrument and area data.
Similar indexed content
NYC-WTC_000270613
TEM analysis parameters and structure identifications; EDS notes included.
Similar indexed content
NYC-WTC_000270370
TEM analysis of samples, 25 mm filter, Oct 2001.
Similar indexed content
NYC-WTC_000293361
TEM analysis header with sample and structure IDs for 10/04/01.
Similar indexed content
NYC-WTC_000237312
Detailed transmission electron microscopy data sheet recording structural identification and measurements for air samples from 40 Rector Street.
Similar indexed content