NYC-WTC_000270121
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
NYC-WTC_000270123OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05'/01
ASBESTOS FIBER- ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS), Method: AHERA Final Rule, EPA Federal Register (40 CFR, Parc 763), Vol. 52, No,. 210, October 30, 1987
Sample, Identification Analysis Parameters
Project/Site: Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5609 - 6OQ5Q Floors 1-10 Date Received: 10/05/01, Grid Openings Analyzed:__ 4
Project Sample No.: SHS-l>10-10/S-43 Average Grid Opening: 106.00 urn
Air Volume: 1872 liters Total Area Analyzed:Q,04SQ jnn^
Filter Type; MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm2 0.0046 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 b.oooo 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 - 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is •! standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A._ Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director-of Electron Microscopy
CITY_21MC100_003099061
NYC-WTC_000270123
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270121
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270100
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270092
Asbestos TEM analysis at Stuyvesant High School, SAED/EDS, Oct 1987.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294052
TEM analysis; sample 5609; air volume and area details.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294072
TEM asbestos analysis at Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293290
Asbestos fiber analysis by TEM for Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270107
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294140
TEM analysis details for Stuyvesant HS project, including opening measurements.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294051
TEM analysis parameters; sample 5609; 70 s/mm2 context.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294076
TEM asbestos analysis at Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270121
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270100
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270092
Asbestos TEM analysis at Stuyvesant High School, SAED/EDS, Oct 1987.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294052
TEM analysis; sample 5609; air volume and area details.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000270121
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similar indexed content
NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
Similar indexed content
NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
Similar indexed content
NYC-WTC_000270100
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
Similar indexed content
NYC-WTC_000270092
Asbestos TEM analysis at Stuyvesant High School, SAED/EDS, Oct 1987.
Similar indexed content