NYC-WTC_000270102
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
NYC-WTC_000270099OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved-N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction <SAED} and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHSRA Final Rule. EPA Federal Register (40 CFR, Part 763). Vol. 52, No. 210, October 30. 1987
Sample Idencification Analysis Parameters
Project/Site: Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5609 - 60025 Floors 1-10 Dace Received: 10/05/01 Grid Openings Analyzed;__ 4
Project Sample No.: SHS-l>10-lQ/5-18 Average Grid Opening: 106-0 0 urn
Air Volume: 1872 lite^ Total Area Analyzed: Q.0450 mm2
Filter Type: MCE 25 mm diam., Pore Size: Q.45 urn Analytical Sensitivity: 22.2 s/mni2 Effective Area: 3 8 S mrn2 0.0046 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0,0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0- 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals {All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Tinalyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003099036
NYC-WTC_000270099
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270102
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294137
TEM analysis for Stuyvesant HS with sample details and opening dimensions.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182510
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294148
TEM asbestos analysis results for Stuyvesant High School building samples, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270190
TEM analysis with SAED/EDS for Stuyvesant High School project.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270086
TEM asbestos analysis results for Stuyvesant High School, floors 1-10; SAED/EDS data.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294054
TEM analysis of 5609; 106.00 µm opening, 0.045 mm2 area.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294067
TEM analysis with EDS/SAED for asbestos at Stuyvesant H.S., Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270100
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294055
TEM analysis; sample 5609; opening 106.00 µm; area 0.045 mm2.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270107
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294139
TEM analysis with SAED/EDS methods for Stuyvesant HS project; notes on air volume.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270102
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294137
TEM analysis for Stuyvesant HS with sample details and opening dimensions.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182510
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294148
TEM asbestos analysis results for Stuyvesant High School building samples, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270190
TEM analysis with SAED/EDS for Stuyvesant High School project.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270086
TEM asbestos analysis results for Stuyvesant High School, floors 1-10; SAED/EDS data.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000270102
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
Similar indexed content
NYC-WTC_000294137
TEM analysis for Stuyvesant HS with sample details and opening dimensions.
Similar indexed content
NYC-WTC_000182510
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
Similar indexed content
NYC-WTC_000294148
TEM asbestos analysis results for Stuyvesant High School building samples, Oct 2001.
Similar indexed content
NYC-WTC_000270190
TEM analysis with SAED/EDS for Stuyvesant High School project.
Similar indexed content