109/25/2001 16:02 FAX 7187291676 KAM CONSULTANTS iao3 5 KAMCOHSUJANTS 35-10 3S!h St rwl Long Island City NewYork.ltlOS Tel; [718)729-1957 Fm; [718)729-1876

BCLK SAMPLE ANALYSIS REPORT CLIENT; Department of Design and Construction - 30-30 Thont.son Avenue, Long I.sland City, NY 11101 BUILDING ADDRESS: WORLD TRADE CENTER - Bldg. # 6 PROJECT#: WOL#: Client Satnple ID# : 6 7 8 9 Lab Sample ID#: 010922A-I385 010922a-1386 010922A-13K7 ()1O922A-1388

Sample Location; 2nd Floor - 2nd Floor - 2nd floor - 2nd Floor - Ceiling Beams Support Colunuu Support Columns Support Columns

Homogeneity: Yes Yes Yes Yes Sample Description: .Spray - on Spray - on Spray - on Spray - on Fire Proofing Fire Proofing Fire Proofing Fire Proofing

Color: Gr Or Gr Gr

Texture: Mixed Mixed M ixed Mixed

Sample Treatment: None None None None

Asbestos Present: (Type & Percent) <1%CHR l.5%CHR ND ND Total Percent Asbestos: <1% 1.5% 0% 0% Other Fibr. Mat. (Type & Percent): 0% 0% 90%FBGL 90%FBGL Non Fibr. Mat. (Percent); >99% 90.5% 10% 10% Date Received: 9/22/01 Date of Analysis; 9/22/01 Date of Report: 9/24/0 1

Analyst: Lab Manage George Kou varas David Chen • Analysis of samoles is oerformed bv Polarized Liyhi Microscoov (PLM) - Point Countine Method (EPA 600/M4-82.02O) • Analytical eouinment.s: Steraobinucular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverine.s and similar non-friable oraanically bound materials. Ouaniitative transmission electron microscopy is currentlv the only method that can be used to determine if this material can be considered or treated as noii-asbestos-containing * Samples will be stored for ninety (90) dav.s and then returned to the client upon reoue.st * The results relate only to the items calibrated or tested. * The certificate of report .shall not be recroduced wirhout the urinen approval of the laboratory. * The repon must not be u.sed by the client to claim cndorsertient bv NVLaP or anv aeenev of the US Government. NYS-DOHELAPH 11273 NIS T->f i'l.A f Hl 02047 AMA tf: 10(1269

2

CITY_21MC100_002821117

NYC-WTC_000269012

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000269012Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000357525

Bulk samples collected at WTC Building 6; analysis reported by Kam Consultants.

Similar indexed content

Bulk sample analysis, PS 89

NYC-WTC_000359423

Bulk sample analysis report for PS 89; samples collected per project records.

Similar indexed content

Compare copies and versions →