NYC 9/11 Public Portal Document
JLC environmental consultants. INC.
200 Pafk Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-81.19 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Dale Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B385
Site: 3 World Financial Center - Floors 3-26
SAMPLE »
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE »
wool 10th Floor/ South East/ East Office (JP)/ GRAY NO 0% CELL 10%
9/28/01 Sample of Debris NFIB 90%
W987
10-001
10002 10th Floor/ South East/ East Office (JP)/ GRAY NO 0% FBGL 30%
9/28/01 Sample of Debris NFIB 70%
10988
10-002
10003 10th Floor/ South East/ East Office (JP)/ GRAY NO 0% CELL , 5%
9/28/01 Sample of Debris FBGL 25%
10989 . NFIB 70%
10-003
10004 10th Floor/ South East/ East Office (JP)/ GRAY NO 0% FBGL 20%
9/28/01 Sample of Debris NFIB 80%
10990
10-004
nNSUFFICIENT MATERIAL SUBMITTED **TEM RECOMMENDED —NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile /Ksbeslos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW° Mineral Wool
CROC = Crocidolite Asbestos FBGL =.Fiberglass
MeihcxJ of Sample Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
. "Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NRB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ’ ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
Olympus PLM, Model BH-2A/M Slereomicroscope, Model ----- .P ZZlxJ.. V, .V. d OTHR = Other
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the wrille
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable Io
samples containing large amounts of fine fibers below the resoliition of the light microscope. The value of this method is limited Io the quantitative identificalion of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was .
determined with a visual volume esb'mate, a calibrated .visual area estimate, and/or point counting procedure. CAUTION; Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in fioor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used Io determine if this material can b
considered or treated as non-asbestos containing.
Page 1 of 3