ITATO ASSOCIATES INC.
New Ycik. New York 10010
www.alc-er.viro.com
212.353,8260
Fax 212.353.6306
November 19, 20 01
Warren t Panzer Encineers, P.C.
228 E. 45th Street"
New York, NY 10017
Attn: Mr. Fabio Pedone
Re; Report of TEM Analysis
Dear Mr. Pedone:
Following are the results of transmission electron rriicroscopy (TSM)
analysis of air samples from our Group Ko. 5928.
Client: NYCDDC
Address: American Express Building
Location: 30th Floor
Samples received: 11/19/01
These results will confirm and document the data transmitted to you
by telephone and Fax today. The analyses were performed in strict
conformance with the methodology of the AHERA Final Rule fCFR
October 30, 1987) for clearance of abatement sites. As indicated
on the attached document, no asbestos structures were detected in
any of the five background samples submitted from the site..
Results reported as Struct/cc are a function of air volume
collected :in the field and are. as such, not verifiable by this
laboratory. This reporr may be reproduced only in its entirety and
not without prior permission of this laboratory. If inside post-
abatement samples pass, the response action may be considered to
have been completed.
The analyses were performed by Dr. .Michael A. Gorycki, Director of
Electron Microscopy.
we are pleased to note that our TEM lab has received full
accreditation from NVLA? and also approval under the NY State DOE
SLAP program, as is currently required for recognized analysis of
TEM air samples for AHERA projects. These analyses were performed
by ATC d/b/a ATC Associates Inc. Please contact me regarding any
questions relating to these materials.
Very truly yours,
Michael A. Gory^i, Ph.D.
Director of Electron Microscopy
CITY_21MC100_010031904
NYC-WTC_000268858
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000268858Source: NYC Law Department, mirrored locally