NYC-WTC_000339441
Corrected addendum on SOF handling and weekly sampling requirements.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Guidance and sampling plan for asbestos in spray-on fireproofing on WTC steel, including weekly sampling and analysis requirements.
NYC-WTC_000268839–000268840OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WTC STEEL BID ADDENDUM # 4 CORRECTED 12/3/01
Best Management Practices (for Recyclers in NJ) for Handling WTC Steel Which May Contain Asbestos in Spray-on Fireproofing (SOF)
NY DOIi and NYC EPA have their own set of guidel.ines that must be adhered to by successful biddei-s in NY State and/or NY City. Sampling of SOF Adhering to WTC Steel. Representative samples must be collected on a weekly basis from each recycler who has received WTC scrap in the previous week. Sufficient samples should be collected each week such that a minimum of 5-10% of new SOF arriving at each facility is sampled. No more than one sample should be taken from each steel member tested. Samples should be analyzed using the method cited in 40 CFR 763 Appendix E, Subpart E, Sect;.on 1, as is currently being used.
EPA and NJDEP/NJDOH reserve the right to oversee sampling operations or to conduct simultaneous sampling to ensure representative sampling. Sample results must be transmitted to EPA and NJDEP electronically within 24 hours of receipt in a spreadslieet format provided by EPA.
Personal Air Monitoring of Workers. Samples are to be collected and analyzed on a weekly basis from at least 10% of workers. Samples sould be taken from workers who are scheduled to work at least 6 hours with WTC scrap on the day of sampling. Whenever possibles, samples are to be taken from workers with the greatest number of hours of exposure on the sampling day. In very dusty conditions, sufficient cassettes should be used to get a reasonalDle estimate of short-term as well as 8 hour exposure. Samples are to be collected and analyzed in accordance with 29CFR 1910, Occupational Exposure to Asbestos and are to be analyzed using Phase Contrast Microscopy (PCM). Sample results must be transmitted to EPA and NJDEP within 24 hours of receipt using the spreadsheet provided by EPA.
Air Monitoring in Residential Areas within 1000 feet of Recycling Operations Air samples must be collected once a week from residential areas within 1000 feet of recycling operations. Samples should be taken using 40 CFR 763 Appendix A to Subpart E- Interim Transmission Electron Microscopy Analytical Methods.
AMEC STEEL BID ADDENDUM 4 CORRECTED 1 01/08/02
CITY_21MC100_002820484
NYC-WTC_000268839
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000339441
Corrected addendum on SOF handling and weekly sampling requirements.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000267175
Addendum for steel bid and asbestos handling for WTC project.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322569
Addendum discussing sampling requirements for spray-on fireproofing on WTC steel.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388765
Addendum/guide on sampling SOF in WTC steel and EPA/NJDEP oversight.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322494
Corr/notes on sampling of spray-on fireproofing and worker monitoring per NY guidelines.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339654
Lab report addendum on SOF asbestos handling; guidelines for bidders and sampling protocols.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188103
Corrected addendum regarding asbestos handling practices and worker monitoring for recyclers of World Trade Center steel scrap.
4 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188105
Document titled WTC Steel Bid Addendum #4 dated December 3, 2001, related to AMEC steel bid specifications.
4 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
3 shared non-person entities · 1 shared topics · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455928
CoC/documents for asbestos-containing exterior sealant/caulking materials for DDC school task force, June 2001.
3 shared non-person entities · 1 shared topics · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104853
Facsimile cover sheet transmitting documents regarding environmental work at 102 Greenwich Street.
3 shared non-person entities · 1 shared topics · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
3 shared non-person entities · 1 shared topics · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000267175
Addendum for steel bid and asbestos handling for WTC project.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339441
Corrected addendum on SOF handling and weekly sampling requirements.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388765
Addendum/guide on sampling SOF in WTC steel and EPA/NJDEP oversight.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322494
Corr/notes on sampling of spray-on fireproofing and worker monitoring per NY guidelines.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339654
Lab report addendum on SOF asbestos handling; guidelines for bidders and sampling protocols.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322569
Addendum discussing sampling requirements for spray-on fireproofing on WTC steel.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000339441
Corrected addendum on SOF handling and weekly sampling requirements.
Similar indexed content
NYC-WTC_000267175
Addendum for steel bid and asbestos handling for WTC project.
Similar indexed content
NYC-WTC_000322569
Addendum discussing sampling requirements for spray-on fireproofing on WTC steel.
Similar indexed content
NYC-WTC_000388765
Addendum/guide on sampling SOF in WTC steel and EPA/NJDEP oversight.
Similar indexed content
NYC-WTC_000322494
Corr/notes on sampling of spray-on fireproofing and worker monitoring per NY guidelines.
Similar indexed content