Concrete report, LIRO Group, WTC A2/A3

Machine-extracted title · confidence 58%

Concrete field inspection report for WTC paving, LIRO Group.

NYC-WTC_000268690
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801, 516-938-7120, 516 938-5107 FAX as ----------------------- ------------- -- ---- —- • CONCRETE REPORT ' lent: LIRO Group/NYC DDC Attn: Mike Bailey Report Date: 8/26/02 Address: Six Aerial Way Report Number: D1345 Lab#: 1799 Syosset, NY 11791 Date Cast: 6/8/02 Project: HWM WTC A2/A3 Contractor: Tully/Grace JV Concrete Plant: Ferrara Bros. Strength PSI: 3200 Yards Placed: FIELD INSPECTION REPO^ ~

Pour Location for Set # 1: Battery PI @ Greenwich St.

Pour Location for Set # 2: Pour Location for Set # 3: Tests made in accordance with ASTM: Yes Not Known X Field Inspector (s) : Client ASTM C 39 COMPRESSIVE STRENGTH TESTS AREA: 28.27 Cylinder Dia: 6" Cylinder ID # Cylinder Set # 1 Date Cast Date Tested Slump Air C143 :173, C23 Unit Wt C138 3 Temp F. Truck C1064 No. Tested Age Load KN strength PSI Required strength Type Frac

T05704 6/8/02 6/17/02 2.5 6.0 72 9 391.5 3,110 3,200 A T05705 6/8/02 7/8/02 2.5 6.0 72 30 502.8 4,000 3,200 A

Cylinder Set # 2

Cylinder set # 3

Remarks: Cylinders Made By Client

Reviewed By: Laboratory Director Richard Kasparian. P.E '9Sts are conducted in accordance with ASTM C-39 or AASHTO T-22. By technicians certified by ACl. Municipal Testing is inspected by the Cement and Concrete Reference Latxiratory of The National institute of

....idards and Technology and is Accredited by: AASHTO ano is Licensed by: New YorX City (019) and by The Slate of Florida. This report relates only to the item or exact iocation/item tested.

not to the entire construction. It can only be reproduced in full, and only with Municipal Testing Laboratory, Inc. written permission. Our liability is strictly limited to the fee paid.

CITY_21MC100_003249318

NYC-WTC_000268690

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268690Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Concrete inspection report, Aug 26, 2002

NYC-WTC_000186701

Field inspection report from Municipal Testing Laboratory regarding concrete strength testing for the HWM WTC A2/A3 project.

Similar indexed content

Compare copies and versions →