NYC 9/11 Public Portal Document
DRAFT
Environmental Monitoring Update
Data reported to NYC DOH 9/24/01 as of 4 pm
Asbestos
Ambient air monitoring
Agency Date Location N N above N above Maximum Comment
samples 0.01 OSHA (fibers/cc)
fibers/cc * PEL @
USEPA 9/20 New Jersey 4 0 0 All were less than detection
limit; highest detection limit was
<0.006 by TEM.
9/19-9/22 Inside controlled 14 1 0 0.037 by Highest was Location #E at
zone PCM South End and Liberty. TEM
was <0.006 (sample 9/22). Also
Location #A at West Broadway
& Barclay PCM = 0.032 and
TEM = 0.015 (sample 9/19).
9/19-9/22 Perimeter of 7 3 0 0.016 by Highest was Location at
controlled zone PCM Broadway and Liberty. TEM
was <0.006. (samples 9/19 were
the 3 elevated samples)
9/19-9/22 Neighborhood near 5 0 0 0.006 by Highest was located at locations
controlled zone PCM #H, #N, #M.. TEM was <0.0064.
9/19/01- Fresh Kills Landfill 10 0 0 All were less than detection
9/20/01 limit; highest detection limit was
<0.008 by TEM.
NYC-DEP 9/22/01- 5 schools, distant 30 0 0 ND (<0.001
9/23/01 from controlled zone by PCM)
o
H
I
k; * Approximately equivalent to indoor clearance level for residences or schools. EPA results by TEM method, NYC-DEP by PCM
to
@0.1 fibers per cc by PCM method; US-OSHA permissible exposure limit for 8 hour time weighted average.
s
O
o
o
I
o
o
to Draft: 9/27/01,11:02 AM \EnvironmentalMonitoringUpdate_9_24
to
Page: 1 of 3
cn
o
co
NYC-WTC_000268369
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000268369Source: NYC Law Department, mirrored locally
Draft report of air monitoring data reported to the New York City Department of Health on September 25, 2001, covering asbestos fiber analysis results.
Draft report of air monitoring data reported to the New York City Department of Health on September 25, 2001, covering asbestos fiber analysis results.
Draft report of air monitoring data reported to the New York City Department of Health on September 25, 2001, covering asbestos fiber analysis results.
Draft report of air monitoring data reported to the New York City Department of Health on September 25, 2001, covering asbestos fiber analysis results.