Lab report: Asbestos sampling, 2/13/02

Machine-extracted title · confidence 32%

OSHA asbestos sampling results and analysis summary at financial district rubble area, with fiber counts and exposure limits.

NYC-WTC_000268347–000268349
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

none-detected. OSHA does not ha ve an exposure limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for the decomposition products of Freon R-22, hydrofluoric acid (HF) and phosgene showed no detectable levels.

Inorganic Acids OSHA has taken approximately 111 samples for inorganic acids such as hydrochloric, phosphoric, and sulfunc acids. Ti ^o samples for sulfuric acid were found to exceed OSHA’s permissible exposure limit (PEL) of 1 mg/m’. Oxides of Nitrogen/ Sulfur: Sampling on grappler operators o i the rubble pile, and on employees at the truck wash stations revealed trace levels of r itric oxide and nitrogen dioxide. SO, personal and area results were found to be below O SHA limits.

Metals: OSHA has taken a total of 1051 ! amples (excluding bulk and blank samples) to monitor worker exposures to dusts, fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium, cobalt, copper, iron, lead, manganese, mercury, molybdenum, nickel, vanadium, dne, cadmium, magnesium, and arsenic. Results from these samples are generally well below the applicable OSHA limits. However, torch cutting and burning structural sti el at the rubble pile have resulted in instances of overexposures as follows: copp-T (13); iron oxide (26); lead (14); and cadmium (2). Accordingly, OSHA is recomme nding that workers engaged in these operations wear appropriate respiratory protection. See information below for the specific counts in regards to mercury.

Mercury OSHA has taken 224 air samples for inorganic mercury. Results for 224 of those air samples have been received and no mercury was detected. Also, 36 bulk samples previously collected from rubble were re-analyzed for mercury and none was detected. Additionally, 10 bulks were taken on 1/3, with one (1) sample detecting mercury at 0.9ppm and nine (9) samples being non-detected. 38 bulk samples were taken between 1/8 and 1/11/02; results indicate 0.1 to 0.2 ppm mostly in around the footprint of Bldg.- 6, and in the pit between WTC tower 1&2.

Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with particular attention to alpha radiation. Results show no elevated levels of concern from either known building latent radiation sources or any terrorist origin source materials.

Page 3 of 3

CITY_21MC100_0 06263227 NYC-WTC_000268349

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268349Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →