Lab report: Asbestos sampling, 2/13/02

Machine-extracted title · confidence 32%

OSHA asbestos sampling results and analysis summary at financial district rubble area, with fiber counts and exposure limits.

NYC-WTC_000268347–000268349
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

drilling the concrete slurry wall, 6) flagging operations in pit, and 7) while chipping concrete with power tools during d :molition activities at 7 WTC’s parking garage. Most of the work areas where apparent o /erexposures to silica occurred were in the rubble pile/pit; an area where OSHA cont nues to encourage the use of respiratory protection. Organic

Compounds: OSHA has taken a total of 636 samples (excluding bulk and blank samples) for organic compounds such as acetaldehyde, icrolein, acrylonitrile, benzene, 2-butanone, carbofurans, dioxin, PCBs, ethyl b mzene, formaldehyde. Freon R-22 (chlorodiflouromethane), hexone, socyanates (e.g. MDI, TDI), perchloroethylene, polynuclear aromatics, phosgene, tyrene, toluene, 1-3 butadiene, trichloroethylene, vinyl chloride, glutaraldehyde, and xyleue. Screening samples initially showed elevated levels of some organic chemicals resultii g from the fires burning in the rubble pile. Subsequent personal and area samples show w orker exposure levels to be below OSHA limits. However, one personal sample res ult for a benzene sample taken was found to be at the 8-hr. OSHA Allowable Limit con ;entration of 1 ppm. This was found on a backhoe operator moving debris on 10/7/0 . See information below for the specific counts in regards to polynuclear aromaucs. Freon R-22, phosgene and dioxin.

Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot spots in (and around the penmeter of) the rubble pile. Dioxin levels detected around the perimeter are lower than those found directly over the pile. To date, only one sample taken on the rubble pile showed dioxin levels which exceeded background levels. Dioxins are considered collectivt ly as suspect human carcinogens. OSHA does not have a PEL for dioxins. Polynuclear Aromatic Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority' of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified eight samples which reached or exceeded OSHA’s coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to strongly recommend the use of respiratory protection when v orking on the rubble pile. Freon R-22, Hydrogen Fluoride & Phosgene: OSHA has taken a total of 202 ; amples for Freon R-22 (chlorodiflouromethane), hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level of 6.4 ppm during the transfer of I reon from the auxiliary' chiller, and all other samples were

Page; of 3

CITY_21MC100_0 06263226 NYC-WTC_000268348

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268348Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →