KAMCONSUIWS 35-40 36th Street Long Island City NewYork,11106 Tel; (718)729-1997 Fax: 718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: OFFICE BLDG. - 346 Broadway PROJECT#: Client Sample ID# : 1 4 s Lab Sample ID# : 010917E-857 010917E-858 0I0917E-859 010917E-860 010917E-86I Sample Location: 12th Floor 12th Floor Middle 12th Floor 9th Floor 9th Floor Stair "A" West Elevation Lobby Stair "B" Window Sill Waiting Area South Windows Between Elevators North Homogeneity: Yes Yes Yes Yes Yes Sample Description: Sill Sill Floor Sill Sill Wipe Wipe V/ipe Wipe Wipe

Color: Blk BIk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 5%SYNTH I0%SYNTH 5%SYNTH 10%SYNTH 5%SYNTH 15%CELL 3%CELL Non Fibr. Mat, (Percent): 95% 90To 80% 90% 92% Date Received: 9/17/01 Date of Analysis: 9/17/01 Date of Report: 9/17/01

Analyst; Roodyjtouis Lab Mana r: J _ i David Chen * A nalysis of samples is performed-bv Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) davs and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. WS DOH ELAP H 11273 yLST-WLAP # 102047 AIHA#: 100269

1

CITY_21MC100_006262596

NYC-WTC_000268315

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268315Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →