Long Island City REPORT OF AIR MONITORING
NewYork, 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS)
Tel: (718)729-1997
Fax:(718)729-1876 CLIENT: DCAS DATE: 10/03/01
PROJECT: ADDRESS: 346 Broadway. Manhattan. NY
12th, 11th, 9th, Sth, Sth, Sth, 4th, 2nd, 1st Floor. Lower Lobby
R W
CLIENT FLOW FLOW SAMPLE FIBERS FIBERS
SAMPLE E O TIME TIME
BEF. AFTER VOLUME PER
LOCATION PER REMARKS LAB ID#
ID# S R IN OUT
(Ipm) (Ipm) (liters) FIELD CC
P K
01 12th Floor - In Room East Wail By Windows 11:32 13:32 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-01
02 12th Floor - East Room By South Stairs to the Roof 11:33 13:33 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-02
03 12th Floor - Elevators' Lobby___________________ 11:34 13:34 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-03
04 12th Floor - Broadway Side Office Middle Hallway 11:35 13:35 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-04
05 12th Floor - Office West Wall By Window_________ 11:36 13:36 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-05
06 11th Floor - Office East Side 11:52 13:52 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-06
07 11th Floor - East Hallway Middle________________ 11:53 13:53 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-07
08 21thj2loor£Elevator Lobby_____________________ 11:54 13:54 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-08
09 11th Floor - West Side Hallway Middle__________ _ 11:55 13:55 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-09
10 11th Floor - West Side Hallway_________________ 11:56 13:56 10 10 1200 _0^ <0.01 Air Quality (Immed. TAT) A011004B-10
11 9th Floor - East Hallway________________________ 12:15 14:15 10 10 1200 <0.055 <221 Air Quality (Immed. TAT) A011004B-11
12 9th Floor - Elevator Lobby Waiting Room_________ 12:16 14:16 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-12
13 9th Floor - Hallway By Exit B____________________ 12:18 14:18 10 10 2200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-13
14 9th Floor - West Hallway By Office_______________ 12:20 14:20 10 10 1200 0.070 £0,01 Air Quality (Immed. TAT) A011004B-14
15 Sth Floor - Reception Hallwa Tiiherciilnsis nept 12:40 14:40 10 10 1200 <0.055 < 0.01 Ajr TAT^ ■AO110015-15
15 Sth Floor - Elevator Lobby______________________ 12:41 14:41 10 22 1200 <0.055 £00? Air Quality (immed. TAT) A0110046-16
17 Sth Floor - Hallway by Exit D____________________ 12:45 14:45 10 10 1200 0.060 <0.01 Air Quality (Immed. TAT) A011004B-17
18 8th Floor - Hallway byRoom 810________________ 12:46 14:46 10 10 1200 <0,055 <0.01 Air Quality (Immed. TAT) A011004B-18
19 Sth Floor - West Side Wall Office________________ 12:48 14:48 22. 10 1200 <0.055 £0,02
<0.055! <0.01
Air Quality (Immed. TAT) A011004B-19
20 6th Floor - East Office Hallway__________________ 13:14 15:15 10 10 1200 Air Quality (Immed. TAT) A011004B-20
21 6th Floor - East Hall Middle 13:16 15:16 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A011004B-21
22 Sth Floor - Elevator Lobby______________________ 13:17 15:17 22 22 1200 <0,055 £0,01 Air Quality (Immed. TAT) A011004B-22
23 Sth Floor - Classroom #3 15:18 10 10 1200 0,070 <0.01 Air Quality (Immed. TAT) A011004B-23
=;
TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY):
TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING,
6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY).
Q
SAMPLING TECHNICIAN: Z.B Nowak / M. Tchatchueng DATE RECEIVED: 10/04/01
H ROTAMETER: KAM- 04 DATE OF ANALYSIS: 10/04/01
1"^
ro DATE OF REPORT: 10/04/01
Analyst: Lab Manager; Vx C
S Deepak Bajracharya David Chen
o
o The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area.
o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program.
I
o The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory.
o
cn The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government.
cn NYS-DOH ELAP # 11273 AIHA # 100269
on 1
CO
<0
NYC-WTC_000268312
OCR can misread numbers and units. Confirm readings against the page image before using them.