Bulk sample analysis, 14-22 [name], Manhattan

Machine-extracted title · confidence 42%

Bulk sample analysis report for NYC-DCAS, listing Lab Sample IDs and sample locations.

NYC-WTC_000268233–000268258
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUANTS 35-40 36th Street Long Island City Mew York, woe Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIOEPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# : 29C 30A 30B 30C 31A

Lab Sample ID# : 0109O5B-225 010905B-226 010905B-227 010905B-228 010905B-229 Sample Location: Roof"B" Roof"B" Rcof"B" Roof"B" Roof'B"

Homogeneity; Yes Yes Yes Yes Yes Sample Description Roof Membrane Roof Membrane Roof Membrane Roof Membrane Base Flashing 3rd Layer ist Laver 2nd Layer 3rd Layer 1 st Layer

Color: Blk Blk Blue Blk Blk Texture; Mixed Fibrous Non Fibrous Mixed Mixed

Sample Treatment: Acid Digestion None Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing Asbestos Present; (Type & Percent) ND ND ND ND 1.37%CHR Total Percent Asbestos: 0% 0% 0% 0% 1.37%

Other Fibr. Mat. (Type & Percent); 60%>FBGL 95%FBGL 0% 35%FBGL 0%

Non Fibr. Mat. (Percent): 40%. 5% 100% 65% 98.63% Date Received: 9/5/01 Date of Analysis: 9/6/01 Date of Report: 9/7/01 Analyst: Va , QlUlWtJci Lab Manager: M. Ulanecki David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M[4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP it 11273 NlST-NELAPtf 102047 AlHAft: 100269

14

CITY_21MC100_0 06262475

NYC-WTC_000268246

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268246Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →