NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Air monitoring report, City Hall phase contrast, 01

Machine-extracted title · confidence 40%

Report of air monitoring using phase contrast microscopy for City Hall area.

NYC-WTC_000268201
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36th Street f Long Island City RbPORT OF AIR MONITORING New York, 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) Tel: (718 729-1997 CLIENT: DCAS DATE: OS/14/01 Fax: (718 729-1876 PROJECT: CITY HALL ADDRESS: CITY HALL -Down Town Manhattan City Hall Basement & 3rd Floor R W CLIENT FLOW FLOW SAMPLE FIBERS FIBERS E O TIME TIME SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# S R IN OUT ID# (Ipm) (Ipm) (liters) FIELD CC P K 01 Locker Room Between 2nd/3rd Floor N/E 19:02 22:02 10 10 1800 <0.055 <0.01 Air Quality A010915B-01 02. 3rd Floor Art Commission Office North 19:04 22:04 10 10 1800 <0.055 <0.01 Air Quality A010915B-02 03 3rd Floor Art Commission Corridor North Side 19:06 22:06 10 10 1800 0.075 <0.01 Air Quality A01O915B-03 04 4th Floor Art Commission Corridor West Side 19:07 22:07 10 10 1800 0.090 <0.01 Air Quality A010915B-04 05 5th Floor Art Commission Corridor South Side 19:08 22:08 10 10 1800 <0.055 <0.01 Air Quality A010915B-05 06 6th Floor Art Commission Corridor East Side 19:09 22:09 10 10 1800 <0.055 <0.01 Air Quality A010915B-06 07 3rd Floor Art Commission South West Office 19:12 22:12 10 10 1800 0.135 <0.01 Air Quality A01O915B-07 08 3rd Floor Art Commission South Coference Room 19:13 22:13 10 10 1800 0.100 <0.01 Air Quality A010915B-08 09 Outside Bldg. South Side _____ ______ _____ 19:15 22:15 10 10 1800 <0.055 <0.01 Air Quality A01O915B-09 10 Basement Room 1A SA/V 21:01 23:01 10 10 1200 <0.055 <0.01 Air Quality A010915B-10 11 Basement Last Room Spiral Stairs N/W_________ 21:02 23:02 10 10 1200 <0.055 <0.01 Air Quality A010915B-11 12 Field Blank <0.055 A010915B-12 13 Field Blank <0.055 A010915B-13

TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY): TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): o SAMPLING TECHNICIAN: Z.B. Nowak DATE RECEIVED: 09/15/01 ROTAMETER: KAM- 04 DATE OF ANALYSIS: 09/15/01 H K [A DATE OF REPORT: 09/19/01 ) I 1 to Analyst: Lab Manager: ____ Z Deepak Bairacharya David Chen S o The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. o The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. I o The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. o cn NYS-DOir ELAP# II273 A/HA # J00269 LO cn 1 LO

O (^

NYC-WTC_000268201

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268201Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →