09/26/2001 10:31 7183900915 SAFETY ENVIRONMENTAL PAGE 02

SAFETY ENVIRONMENTAL (718) 390-0914 CO. OF N.Y. INC. Fax (718) 390-0915

33 Clinton Avenue Staten Island, NY 1C301 ’'**aiIENT: NTC D.O.T. SITE: 51 CHAMBERS STREET, NEW YORK, NY RE: ASBESTOS AIR MONITORING AND TESTING 1,2,3,4 FL EXIT Z STAIRWAYS DATE SAMPLE COLLECTED: 9/21/01 DATE SAMPLE ANALYZED: 9/24/01 FILE NO.: 01-137 BATCH t: 9-015 SAMPLK TYPE; XIR QOXLITY CZRTIFICATZ OF ^lNALYSIS Airborne asbestos analysis by NIOSH method no. 7400-phase contrast microscopy Mew York State ELAP # 11475, .American Industrial Hygiene association # 17049 . Microscope Type-P'TM, Make-Olympus , Model CH-2 SAMPLE SAMPXZ LOCATION I TOTAL FLOW VOLUME RESULTS NUMBER j TIME RATE (L) FIBERS/ SAMPLIQ) (L/Min) CC (XIN) Pl 4 FL EX E ENT STAIRWAY 60 15 900 0.007 CENTER 4FL EX E STAIRWAY 60 15 900 0.004 "pj CENTER 4FL EX E STAIRSTEP 60 15 900 0..005 P4 I 3FL EX E ENT STAIRWAY 60 15 900 0.004 ?5 CENTER 3FL EX E STAIRWAY 60 15 900 0.005 P6 , CENTER 3FL EX E STAIRSTEP ! 60 15 900 0.004 P7 2FL EX E ENT STAIRWAY 60 15 900 0.008 P8 ' CENTER 2FL EX E STAIRWAY 60 15 900 0.007 P9 J CENTER 2FL EX E STAIRSTEP 60 15 900 0.007 PIO I IFL EX E ENT STAIRWAY 60 ! 15 900 0.004 Pll CENTER IFL EX E STAIRWAY 60 15 900 0.005 P12 CENTER IFL EX E STAIRSTEP 60 15 900 0.009 Pl 3 i BLANK ND "blank 1 i ND

ine Kozlovskaya*^ Francis Owoh M.S., RPIH laboratory Analyst Laboratory Director Environmental Engineering Consultant • Asbestos, Lead, and Gas Air Monitoring Testing, Inspections Project Management • Laboratory Analytical Testing Services • Abatement Design • Phase 1 & 2

CITY_21MC100_006262385

NYC-WTC_000268189

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268189Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →