Air monitoring report, DCAS project, Mar 2001

Machine-extracted title · confidence 41%

Phase contrast microscopy analysis of air filters for DCAS, address 80 [name].

NYC-WTC_000268139
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 361h Street < f Long Island City REPORT OF AIR MONITORING New York, 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) Tel: 718 729-1997 CLIENT: DCAS DATE: 03/28/01 Fax: 718 729-1876 PROJECT: ADDRESS; 80 Centre Street, Manhattan sth. Sth, 4th, 3rd, Main Floor & Yard Level R W CLIENT FLOW FLOW SAMPLE FIBERS FIBERS E O TIME TIME SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# S R IN OUT ID# (Ipm) (Ipm) (liters) FIELD CC P K 01 Sth Floor - Stairs D Exit 13:10 15:10 10 10 1200 0.080 0.0030 Air Quality (Immed. TAT) A010929F-01 02 Sth Floor - North Corridor By Room 8N 13:12 15:12 10 10 1200 0.070 0.0030 Air Quality (Immed. TAT) A010929F-02 03 Sth Floor - Stairs E Exit 13:14 15:14 10 10 1200 0.060 0.0020 Air Quality (Immed. TAT) A010929F-03 04 Sth Floor - Elevator Lobby 13:16 15:16 10 10 1200 0.070 0.0030 Air Quality (Immed. TAT) A010929F-04 05 Sth Floor - Stairs C Exit 13:17 15:17 10 10 1200 0.080 0.0030 Air Quality (Immed. TAT) A010929F-05 06 6th Floor - Stairs D Exit 13:40 15:40 10 10 1200 0.120 0.0050 Air Quality (Immed. TAT) A010929F-06 07 Sth Floor - Stairs C Exit 13:42 15:42 10 10 1200 0.150 0.0060 Air Quality (Immed. TAT) A010929F-07 08 6th Floor - Elevator Lobby_______________ 13:43 15:43 10 10 1200 0.130 0.0050 Air Quality (Immed. TAT) A010929F-08 09 6th Floor - North West Corridor 13:45 15:45 10 10 1200 0.110 0.0050 Air Quality (Immed. TAT) A010929F-09 10 6th Floor - North East Corridor 13:46 15:46 10 10 1200 0.140 0,0060 Air Quality (Immed. TAT) A010929F-10 11 4th Floor - Freight Elevator Lobby________ 13:59 15:59 10 10 1200 0.090 0.0040 Air Quality (Immed. TAT) A010929F-11 12 3rd Floor - Corridor North West 14:10 16:10 10 10 1200 0.060 0.0020 Air Quality (Immed. TAT) A010929F-12 13 3rd Floor - Corridor North Middle 14:12 16:12 10 10 1200 <0.055 <0002 Air Quality (Immed. TAT) A010929F-13 14 3rd Floor - By Elevator Lobby____________ 14:14 16:14 10 10 1200 <01055 <0.002 Air Quality (Immed. TAT) A010929F-14 15 3rd Floor - Corridor South Middle 14:16 14:16 10 10 1200 <0.055 <0.002 Air Quality (Immed. TAT) A010929F-15 16 3rd Floor - Corridor South West 14:18 14:18 10 10 1200 <0.055 <0.002 Air QiiAlity (Immed. TAT) A010929F-16 17 Main Floor - Lobby Centre Street Entrance 14:44 16:44 10 10 1200 <0.055 <0.002 Air Quality (Immed. TAT) A010929F-17~ 18 Main Floor - Hogan Street Entrance 14:46 16:46 10 10 1200 0.070 0.0030 Air Quality (Immed. TAT) A010929F-18 19 Main Floor - Room 103 r4^ 16:48 JO JO. 1200 0.090 0,0040 Air Quality (Immed. TAT) A010929F-19 20 Yard Level - By Stairs C 15:10 17:10 10 JO 1200 0.100 0.0040 Air Quality (Immed. TAT) A010929F-20 21 Yard Level - Electrical Room 15:15 17:15 10 10 1200 <0.055 <0.002 Air Quality (Immed. TAT) A010929F-21 22 Field Blank <0.055 A010929F-22 23 Field Blank <0.055 A010929F-23 24 Field Blank <0055 A010929F-24

TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY): TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING. 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): o SAMPLING TECHNICIAN: M. Tchatchueng, Z.B. Nowak DATE RECEIVED: 03/29/01 H K ROTAMETER: KAM- 04

2 DATE OF ANALYSIS: 09/29/01 I to DATE OF REPORT: 10/01/01 s o Analyst: 1 David Ch^ Lab Manager: 1 JU David Chen o The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. o I KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. o o The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory. to The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. to NVS-DOH ELAP # J1273 Af/LA fl IM269 to 1 co

NYC-WTC_000268139

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268139Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →