NYC-WTC_000268225
Report of phase contrast microscopy air monitoring at City Health Building, DCAS project.
3 shared non-person entities · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗DCAS air monitoring report for project at 60 [name], using phase contrast microscopy.
NYC-WTC_000268136OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
KAM CONSULTANTS 35-40 36th Street ( t Long Island City REPORT OF AIR MONITORING New York. 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) Tel: 718)729-1997 Fax: 718)729-1876 CLIENT: DCAS DATE: 09/18/01 PROJECT: ADDRESS: 60 Centre Street, Manhattan, NY
R W CLIENT FLOW FLOW- SAMPLE FIBERS FIBERS E O TIME TIME SAMPLE LOCATION BEF. AFTER VOLUME PER PER REMARKS LAB ID# S R IN OUT ID# (Ipm) (Ipm) (liters) FIELD CC P K 24 IWA - Room 252_______________________ 21:55 22:55 15 15 900 0.060 <0.01 Air Quality (Immed. TAT) A010919A-24 25 IWA - Corridor 248-252_________________ 22:00 23:00 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-25 26. IWA-Corridor 228-232_________________ 22:02 23:02 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-26 27 IWA-Corridor 208-212_________________ 22:04 23:04, 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-27 IWA-Room 212_______________________ 22:06 23:06 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-28 21 IWA - Ground Floor by Main Entrance 23:16 0:16 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-29 30 IWA - Main Hall Middle By Main Entrance 23:18 0:18 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-30 31 IWA - Ground Floor Voucher Area 23:19 0:19 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-31 32 IWA - Ground Floor 119 23:21 0:21 15 15 900 <0.055 <0.01 Air Quality (Immed TAT) A010919A-32 33 IWA-Ground Floor 139 23:23 0:23 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-33 34 IWA - Basement by East Entrance_______ 23:33 0:33 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-34 35 IWA - Basement County Clerk Room 109B 23:35 0:35 15 15 900 <0,055 <0.01 Air Quality (Immed. TAT) A010919A-35 36 IWA - Basement County Clerk Room 109B 23:36 0:36 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-36 37 IWA-Basement Hall By 117 B__________ 23:38 0:38 15 15 900 0.065 <0.01 Air Quality (Immed, TAT) A010919A-37 38 IWA-Basement Hall By 103 B 23:40 0:40 15 15 900 <0.055 <0.01 Air Quality (Immed. TAT) A010919A-38 33 Field Blank <0.055 A01091SA-3S 40 Field Blank <0.055 A010919A-40 41 Field Blank <0.055 A010919A-41 42 Field Blank <0.055 A010919A-42
TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY): TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING, 6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY): o SAMPLING I LCIINICIAN: Z.U. Nowak / P. Sroka DATE RECEIVED: 09/19/01 ROTAMETER: KAM- 04 DATE OF ANALYSIS: 09/19/01 DATE OF REPORT: 09/19/01 to Analyst: Lab Manai S ueepak bajracharya uavia onen O The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area. o o KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program. I The results relate only to the items calibrated or tested. The certificate ol report shall not be reproduced without approval of the laboratory. o o The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. ,\'YS-DOH ELAP a H273 A IHA » 100269 2 cn
NYC-WTC_000268136
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000268225
Report of phase contrast microscopy air monitoring at City Health Building, DCAS project.
3 shared non-person entities · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268211
Air monitoring report for DCAS at 125 [name], Manhattan, with fabric/times noted.
4 shared non-person entities · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268389
Phase Contrast microscopy air monitoring report for LIC building; summarizes results and method.
2 shared non-person entities · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268159
Report of air filter analysis via phase contrast microscopy for 111 [name] building.
3 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268164
Phase contrast microscopy analysis of air filters for DCAS project at 137 [name] Street; client: NYC-DCAS; date 10/01/01.
4 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268312
Air monitoring report for 346 Broadway site, phase-contrast microscopy of air filters.
4 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268271
Air monitoring report using phase contrast microscopy for 125 [name], Manhattan.
3 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268148
Phase contrast microscopy analysis of air filters for DCAS project at 100 [name].
4 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268383
Air monitoring report for Phase Contrast Microscopy analysis; Long Island City client: DCAS.
2 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000266388
Air filter phase-contrast microscopy analysis for OCAS project, Manhattan.
3 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182324
Report of air monitoring results for the 19th floor of a Manhattan building using phase contrast microscopy.
4 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268175
Report of air monitoring and phase-contrast microscopy analysis of air filters for DCAS project.
3 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000178182
Laboratory report from KAM Consultants detailing phase contrast microscopy results of air filters collected for DCAS.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178198
Laboratory report from KAM Consultants detailing phase contrast microscopy results of air filters collected for DCAS on September 18, 2001.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268225
Report of phase contrast microscopy air monitoring at City Health Building, DCAS project.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251651
KAM Consultants pollution/air sampling documentation for WTC crisis emergency projects.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268389
Phase Contrast microscopy air monitoring report for LIC building; summarizes results and method.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268312
Air monitoring report for 346 Broadway site, phase-contrast microscopy of air filters.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Report of phase contrast microscopy air monitoring at City Health Building, DCAS project.
Similar indexed content
NYC-WTC_000268211
Air monitoring report for DCAS at 125 [name], Manhattan, with fabric/times noted.
Similar indexed content
NYC-WTC_000268389
Phase Contrast microscopy air monitoring report for LIC building; summarizes results and method.
Similar indexed content
NYC-WTC_000268159
Report of air filter analysis via phase contrast microscopy for 111 [name] building.
Similar indexed content
NYC-WTC_000268164
Phase contrast microscopy analysis of air filters for DCAS project at 137 [name] Street; client: NYC-DCAS; date 10/01/01.
Similar indexed content