Microvac sample data and chain of custody, TRC

Machine-extracted title · confidence 62%

Wipe sample information and chain of custody details for TRC.

NYC-WTC_000267587–000267616
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document SciLab Job ^202012746 Client N^^^TRC Environmental Corporation < TabiM Summary of Transmission Electron Microscopy (TEM) Results for Asbestos (ASTM 5755 Dust) 35052-0000-00002; New York City Law Department; 100 Church Street Surface * Analytical Structure * Analytical Structure Area Asbestos Sensitivity Density Sensitivity Density Type SciLab Client Sampled Dilution Structures on Grid on Grid on Surface on Surface of Sample # Sample # (sq. cm ) Factor Detected (Str / sq mm) (Str / sq mm) ( Stri sq. cm ) (Str/ sq. cm ) Asbestos 01 JD012102MV21SAH15 100.0 0.020 1 10 10.0 1,070 1,070 chrysotile 21st Floor; Supply Air Handler #15-Mixing Chamber Base of Cooling Coils 02 JD012102MV21SAH11 100.0 0.005 11 10 110.0 4,280 47,080 chrysotile 21st Floor; Supply Air Handler #11-Mixing Chamber Base of Cooling Coils 03 JD012102MV21RAHF12 100.0 0.100 143 33.3 4,766.7 713 102,006 chrysotile 21st Floor; Return Air Handler-Fan #12 Floor of Air Duct 04 JD012102MV21SAH10 100.0 0.020 0 10 <10 1,070 <1,070 NSD 21st Floor; Supply Air Handler #10-Mixing Chamber-Base of Cooling Coils 05 JD012102MV21SAH08 100.0 0.020 3 10 30.0 1,070 3,210 chrysotile 21st Floor; Supply Air Handler #08-Mixing Chamber-Base of Cooling Coils 06 JD012102MV21SAH07 100.0 0.020 1 10 10.0 1,070 1,070 chrysotile 21 st Floor; Supply Air Handler #07-Mixing Chamber-Base of Cooling Coils 07 JD012102MV21SAH14 100.0 0.100 0 25 <25 535 <535 NSD 21st Floor; Supply Air Handler #14-Mixing Chamher-Rase of Cooling Coils 08 JD012102MV21RAHF09 100.0 0.100 0 25 <25 535 <535 NSD Return Air handler-Fan #09 09 JD012102MV21SAH01 100.0 0.002 6 10 60.0 8,560 51,360 chrysotile 7th Floor; Supply Air Handler #01-Mixing Chamber-Base of Cooling Coils 10 JD012102MV07RAH20 100.0 0.100 13 25 325.0 535 6,955 chrysotile 7th Floor; Return Air Handler-Fan #20-Base of Duct 11 JD012102MV07SAH02 100.0 0.010 17 10 170.0 2,140 36,380 chrysotile 7th Floor; Supply Handler#02; Mixing Chamber-Base of Cooling Coils 12 JD012102MV07SAH03 lOO.O 0.020 34 10 340.0 1,070 36,380 chrysotile o 7th Floor; Supply Handler#03-Mixing Chamber-Base of Cooling Coils A 13 JD012102MV07SAH04 100.0 0.005 9 10 90.0 4,280 38,520 chrysotile b< I 7th Floor; Supply Handler#04-Mixing Chamber-Base of Cooling Coils NJ

I o 14 JDO12102xMV07RAHF21 100.0 7th Floor; Return Air Handler-Fan #21-Base of Duct 0.100 25 25.0 535 535 chrysotile

o structure density represented by the detection of 1 structure I * not analyzed o o FSD: No Asbestos Structures Detected Date: 1/23/02 Reviewed By; Analyzed By; ro Aleksstndr Barengolts ' O'. '.O'

NYC-WTC_000267590

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000267590Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →