Microvac sample data and chain of custody, TRC

Machine-extracted title · confidence 62%

Wipe sample information and chain of custody details for TRC.

NYC-WTC_000267587–000267616
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

sample area TEM Asbestos (dust) Count Sheet analyzed

Client Name: TRC Environmental Corporation Job#: 202012746 Volume (milliters): 50 w Lab Sample #: 06 Dust Sample Area: 100 Client Sample #: JD012102MV21SAH07 Filter Type / Filter Area: MCE 214 mm2 Received: 01/21/2002 20;09;31 Grid Opening Size: 0.01 [tlilB Date Analyzed: 01/23/2002 Area Examined: 0.10000 mtn2 Scope #: Dilution Factor: 0.0200 Magnification: 20,000 Accelerating Voltage: 100 KeV Analysis Performed by: Aleksanflr Barengolts Location Grid Fiber Length Width Opening gM gM Fiber Type Morphology EDS Orient. SAED Photo C5-6/1C 1 NSD □ C5-6/1E 2 NSD U C5-6/1F 3 NSD U C5-6/1G 4 NSD U C5-6/1H 5 1 3 0.1 Chrysotile Matrix Mg, Si, Fe \ C5-4/1H 6 NSD u C5-4/1K 7 NSD u D1-3/4C 8 NSD □ ni-3/4E 9 NSD u O-3/4G 10 NSD u w

NSD; No Asbestos Structures Detected Comments: Structure Density Grid Evaluation Total Grid Openings: 10 (str/sq mm) Grid Openings Covered > 50% Chrysotile Asbestos Structures: 1 10.0 K Intact Grid Opening > 50% Amphibole Asbestos Structures: 0 <10 Undissolved Filter < 10% Asbestos Structures >=5 microns: 0 <10 KI Folded Replica < 50% Total Asbestos Structures: 1 10.0 K Filter Loading < 25% Analytical Sensitivity: 10 K Particulate Even CITY_21MC100_0 06261476

NYC-WTC_000267597

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000267597Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →