SciLabJob#: 201113793
Client Name: Total Safety Consulting, LLC
Table I
Summary of Bulk Asbestos Analysis Results
Turner Construction; 30 W. Broadway, (Fiterman Hall), NY
SciLab Client HG Sample Heat Acid Insoluble
Sample Sample# Area Weight Sensitive Soluble Non-Asbestos Asbestos by Asbestos by
# Location (gram) Organic % Inorganic % Inorganic % PLMTDS TEM
01 Blank NVA NA
Blank
02 13C NVA NA
131 Floor South "C
03 9C NVA NA
9th Floor South "C
04 4C NVA NA
4th Floor South "C"
05 IC NVA NA
1st Floor South "C"
Analyzed by: John Koubiadis, Date Analyzed: 11/30/01
o ♦NAD/NSD = no asbestos detected; NA = not analyzed; NA/PS = not analyzed / positive stop; PLM Bulk Asbestos Analysis by EPA 600/M4'82-020 per 40 CFR 763 (NVLAP Lab #200546-0) and ELAP PLM Analysis
H Protocol 198.1 for New York samples (NYSDOH ELAP Lab # 11480); ELAP TEM Analysis Protocol 198.4 for negative NY NOB samples: Note: PLM is not consistently reliable in detecting asbestos in floor coverings
K and similar non-friable organically bound materials. TEM is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing in New York State (also see
I
EPA Advisory for floor tile, FR 59, 146, 38970, 8/1/94). National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of
I—i
s
o
the laboratory. This PLM report relates ONLY to the items tested.
AIHA# 102843: VTCert#^^^^5 NVA=No Visible Asbestos
o
o
I Reviewed Dy:
o
o
co
co
co
NYC-WTC_000266934