Table I
Summary of Bulk Asbestos Analysis Results
Turner Construction; Fiterman Hall - 30 W. Broadway, NY, NY
SciLab Client HG Sample Heat Acid Insoluble
Sample Sample# Area Weight , Sensitive Soluble Non-Asbestos Asbestos by Asbestos by
# Location (gram) Organic % Inorganic % Inorganic % PLM/DS TEM
01 FM-01 NA NVA
14 1/2 Stair C - Fl. - South
02 FM-02 NA Chrysotile Present
12th Stair C - Fl, South
03 FM-03 NA Chrysotile Present
9th Stair C - Fl. - South
04 FM-04 NA Chrysotile Present
7th Fl. C - South
05 FM-05 NA NVA
4th Fl. Stair C - South
06 FM-06 NA NA
Blank
07 FM-07 NA NA
Blank
Analyzed by: Mark Peysakhov. Date Analyzed: 12/21/01
o *NAD/NSD = no asbestos detected; NA = not analyzed; NA/PS = not analyzed / positive stop; PLM Bulk Asbestos Analysis by EPA 6007M4-82-020 per 40 CFR 763 (NVLAP Lab #200546-0) and ELAP PLM Analysi
Protocol 198.1 for New York samples (NYSDOH ELAP Lab# 11480); ELAP TEM Analysis Protocol 198.4 for negative NY NOB samples; Note: PLM is not consistently reliable in detecting asbestos in floor coverings
H
K and similar non-friable organically bound materials. TEM is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing in New York State (also see
I
NJ EPA Advisory for floor tile, FR 59,146, 38970, 8/1/94). National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of
s
O
I—i
the laboratory. This PLM report relates ONLY to the items tested.
AIHA# 102843; VT Cert# ALOI6055 NVA=No Visible Asbestos
o
o
Io Reviewed By:.