CLIENT:SCHOOL CONSTRUCTION AUTHORITY SITE: LDSHP HS 90 TRINITY PL PROJECT-NoTc1^^0?03 DATE: Hovsrrber 20, 20 01 PURPOSE OF MONITORING: AREA SAMPLING TECHNICIAN: G. LOPEZ CASET SIZE : 25min ROTOMETER #: GLOOl LLW# JOB # ATHENICA J ENVIRONMENTAL SERVICES BATCH #01-11-068 (718) 784-7490 TYPE-OF-RESPIRATOR TYPE-OF-REMOVAT COMMENTS : i FAX (718) 784-4085 HALF FACE CLEAN UP RM 1209,1103,1003,705,602,604, 607,713,6 FL BRDG-FINALS

SAMPLE (*) TIME TOTAL FLOW LOCATION TYPE PUMP VOLUME FIBERS/ FIBERS/ ID # IN OUT MIN. BEFORE AFTER AVERAGE FIELD C.C. 01 IN ROOM 1209 CENTER IWA 01:00 02:30 90 14.0 14.0 14.0 1260 <.10 . 004 02 IN ROOM 1103 CENTER IWA 01:01 02:31 90 14.0 14.0 14.0 1260 . 10 <.004 03 IN ROOM 1003 CENTER IWA 01:02 02:32 90 14.0 14.0 14.0 1260 <.10 . 004 04 IN ROOM 005 CENTER IWA 01:03 02:33 90 14.0 14 . 0 14.0 1260 . 10 . 004 05 IN ROOM 313 CENTER IWA 01:04 02:34 90 14.0 14.0 14.0 1260 0.10 0.004 06 IN ROOM 602 CENTER IWA 01:05 02:35 90 14.0 14.0 14.0 1260 .10 . 004 07 IN ROOM 604 CENTER IWA 01:06 02:36 90 14.0 14.0 14.0 1260 <.10 . 004 03 IN ROOM 607 CENTER IWA 01:07 02:37 90 14.0 14.0 14.0 1260 <.10 . 004 09 6TH FL BRIDGE OPP RM 605 TWA 01 : 08 02:38 90 14.0 14.0 14.0 1260 . 10 <• 004 10 IN ROOM 713 IWA 01:09 02:39 90 14.0 14.0 14.0 1260 <.10 <.004 11 FIELD BLANK 0.00 12 FIELD BLANK 0.00

n *OWA -Outside work area IWA -Inside work area ICR •Inside clean room IFNL -Inside Finals OFNL -Outside Finals ro PRE • Preabatement OB -Outside building NGAE -Negative air exhaust OTH -Other S n Above samples analyzed by Phase Contrast Microscopy (PCM) per NIOSH 7400 Method (ELAP ^10955). Analyzed By :

Athenica Environmental Services Inc. (.AES) is responsible only , _____________ for information pertaining to samples taken by its employees. Spiro*!. Doiigaris, AES shall not be liable for information arising from samples Laboratory Director

LO L J arU Lt C -s Jid C JrogE.. 3. L J C. 1 C J E... .3 03 L3 ri CJ ri El iPag 1 r-1 LO

NYC-WTC_000266888

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266888Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →