NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

Bulk sample analysis report, NYC-DCAS, 60 Manhattan

Machine-extracted title · confidence 42%

Laboratory analysis of bulk samples for NYC-DCAS at 60 Manhattan building address.

NYC-WTC_000266372–000266383
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUITANTS 35-40 36th Street Ung Island City NewYork.11106 Tel; (718)729-1937 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 60 Centre Street, Manhattan, NY PROJECT#: Client Sample ID" • 6 7 S 9 lO Lab Sample ID^/ 010919B-I127 010919B-1I28 010919B-1129 010919B-1130 010919B-11J1

Sample Location 7th Floor 7th Floor 7th Floor 7th Floor 7th Floor Lobby Vent Meeh Room 1 Meeh Room 1 Room 769 Conference Rm Exhaust Inside Duct of Inside Duct of Window Sill Window Sill MC-AHU-7-4 MC-AHU-7-3 West Wall Homogeneity. Yes Yes Yes Yes Yes

Sample Description Dust Dust Dust Dust Dust Wipe Wipe Wipe Wipe Wipe

Color Blk Blk BIk Blk Blk

Texture. Mixed Mixed Mixed Mixed Mixed

Sample Treatment None None None None None

Asbestos Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos; 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent) 15%SYNTH 2%CELL 2%CELL 3%SYNTH 5%SYNTH 1%FBGL <1%FBGL Non Fibr Mat (Percent). 85% 97% 97% 97% 95% Date Received. 9/19/01 Date of Analysis 9/19/01 Date of Report 9/19/01

Analyst: Lab Manage Roody L^is David Chen * Analysis of samples is performed by Pi/arized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJ EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron micro: copy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then return'-d to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. ♦ The report must not be used by the client to claim endorserrent by NVLAP or any agency of the US Government. i\YS-DOll ELAP » 11273 MST-.MLAP/i 02047 AIHA »: 100269

2

CITY_21MC100_0 02777725

NYC-WTC_000266373

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266373Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →