Bulk sample analysis report, DCAS, 253 Broadway

Machine-extracted title · confidence 66%

Bulk analysis report for DCAS project; multiple lab IDs and floor locations across 14th floor.

NYC-WTC_000266334–000266338
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUAMTS 35-40 36th Street Long Island City NewYork, 11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: OFFICE BLDG. - 253 Broadway, Manhattan, NY PROJECT#: Client Sample ID# . 1 4 5 Lab Sample ID# : 010917C-890 0I0917C-891 010917C-892 010917C-893 010917C-894

Sample Location; Mens Bathroom 14th Floor 14th Floor 14th Floor 14th Floor Windows East Side Room West Room South Side South Side 14th Floor West Wing East Wing Homogeneity: Yes Yco Yes Yes Yes

Sample Description; Sill Floor Sill Floor Floor Wipe Wipe Wipe Wipe Wipe

Color. Blk Blk Blk BIk Blk

Texture; Mixed Mixed Mixed Mixed Mixed

Sample Treatment; None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat, (Type & Percent); 15%SYNTH 2%SYNTH 5%SYNTH 3%CELL 10%SYNTH 10%CELL 5%CELL 8%CELL <1%FBGL Non Fibr. Mat. (Percent): 75% 93% 87% 97% 89% Date Received: 9/17/01 Date of Analysis: 9/17/01 Date of Report: 9/17/01

Lab Manage(f Roo^ Louis David Chen * Analysis of samples is performedjjv Polarized Light Mier jseopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEI. I E.MT-Serial ft 25930). Polarized Light Microscope (MEIJI ML-POL-Serial ft 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron micrc scopv is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returr ed to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without th: written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP ft 11273 NIST-NyLAPft 102047 AIHAff: 100269

1

CITY_21MC100_002777686

NYC-WTC_000266334

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266334Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →