Asbestos inspection, 130 Liberty Street, Oct 2008

Machine-extracted title · confidence 42%

Asbestos inspection record for 130 Liberty Street with inspection details and photos.

NYC-WTC_000266037
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 10/02/08 Floor Zip Borough Block Lot Squad # Badge # Various 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU0086MN08 No Contractor’s Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 9:30 am to 10:30 am

I arrived at the premise at 9:30 am. LVI schedule informed that activities include cleaning work area on IS'” and 12“’floors.

I proceeded to the decon, don personal protective equipment as appropriate for the abatement work area and entered containment on 13'” floor. Negative air pressure on the floor, documented by manometric measurement, was 0.073.

IS'” Floor - 21 people were performing work on site. Workers were inspecting and re-sealing the critical barriers, floor, columns around the shaft area, cleaning ceilings, beams, columns in the area 4, cleaning the floors around the work areas and vacuuming up the water from the ceiling cleaning. Other workers were preparing boxes. 16 Gaylord boxes were ready for load out. I observed electrical wires hanging to the floor, duct tape on the door of electrical room was detached. Supervisor on the floor was advised to direct workers to re-seal the electrical room and pull up electrical cables. Inspection was done on micro trap machines and micro trap tents. Air monitoring pumps were on. I used ladder to proceed to the 12"’ Floor.

12"’ Floor - 16 people were present on site. Workers were cleaning and vacuuming up the water from the floor on the West side of work area, sealing around the shaft area, re-sealing the critical barriers and a top of the tents, plasticizing the floor, preparing boxes, removing debris and dust from the ground and placing into the boxes, fine spraying with amended water. 20 micro trap machines were powered on and 5 were on stand by. Inspection was done on micro trap tents. Using ladder I proceeded back to the 13’" Floor.

After following the decontamination procedure I signed the log book and used north hoist to get to the ground floor. Inspection was done on ATC trailer.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Superviso^^nitial

Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130975

NYC-WTC_000266037

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266037Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000266100

Asbestos inspection page for 130 Liberty Street including location data and owner name, dated 11/04/08.

Similar indexed content

Compare copies and versions →