TEM air analysis, 130 Cedar Street, Apr 2008

Machine-extracted title · confidence 28%

Preliminary TEM air analysis lab report for 130 Cedar Street building.

NYC-WTC_000265808–000265809
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

R] Lee Group, Inc. 35f) Hochberg Road, Monroeville, PA 15146 Tel: (724)325-1776 I Fax:(724) 733-1799

Preliminary Laboratory Report TEM Air Analysis Mr. Chris Colboume Report Date. 4/5/2008 Masterworks Development Corporation Sample Receipt Date; 4/5/2008 56 West 45th Street RJ Lee Group Job No.: TLN704891-568 4th Floor Samples Received. 1 New York, NY 10036 Building: 130 Cedar Street Sampling Event: Health and Safety

Method: Federal Register, 40 CFR, Part 763, October 30, 1987

Concentration Sample Collection Filter Area Asbestos Analy'tical RJLG Sample Sample start oats-rime Area Volume Analyzed structures Sensitivity Number Type EndDate-Tirne Floor-Sub Location-Location (mn^) (liter) (mn?) Chry Amph (S/mn?) (S/cc)

5276308.HT Area 4/3/2008 - 15:19:00 (Roof) - South - Phase 3C 385 1743 0.1179! 0 0 <8.5 <0.002 4/3/2008 - 23:37:00 Personnel Decon Clean Room 8.5 0.002

Notes: 1. Volumes provided by RJ Lee Group, Inc. were used to calculate analytical results and sensitivities. 2. “<” indicates results less than analytical sensitivity. ” indicates that sample was not analyzed. 3. Sample(s) for this project were analyzed at our: Monroeville, PA (AIHA #100364, NVLAP #101208-0, NY ELAP #10844) facility. 4. If RJ Lee Group, Inc. did not collect the samples analyzed, the verifiability of the laboratory's results are limited to the reported values. 5. Abbreviations: N/A-Not Applicable, Chry-Chrysotile Asbestos, Amph-Ampliibole Asbestos, S-Structures. 6. Samples will be held for 90 days and then disposed of per Federal regulations. 7. These results are submitted pursuant to RJ Lee Group's current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which these results are used or interpreted.

Page 1 of 2

CITY_DEP_WORBY_CANNATA_SUBP_000130134

NYC-WTC_000265808

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265808Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000424165

Final TEM air analysis report dated 3/19/2005 for building 4.

Similar indexed content

NYC-WTC_000425751

Final TEM air analysis report for building 4, dated 3/19/2005.

Similar indexed content

NYC-WTC_000425765

Final TEM air analysis report for building 4, dated 3/19/2005.

Similar indexed content

NYC-WTC_000425941

Final TEM air analysis report for building 4, dated 3/19/2005.

Similar indexed content

NYC-WTC_000232218

Final laboratory report from RJ LeeGroup documenting TEM air analysis results for Building 4 dated March 2005.

Similar indexed content

Compare copies and versions →