NYC-WTC_000369041
TEM asbestos analysis performed; project cleanup details and samples listed.
6 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis performed for DEP cleanup; ATC project 22906-0002, Oct 2002.
NYC-WTC_000265652–000265653OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document 1^002 1O/1O/.2OO2 07:44 FAX 212 353 8306 ATC
ATC Associates 104 East 25 Street, New York, NY 10010 Phone; (212) 353-8280 Fax: (212)353-8306
- Attn: Benjamin Sallemi Received: 10/8/02 11 10.00 aM ATC Associates Inc ATC Group 8943 ; 104 East 25th Street Analysis Date: 10/9/02 New York NY 10010 Fax: (212)353-3599 Phone; (212)353-8280 Project; DEP Cleaa-up ATC Project #: 22906-0002 125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Arta Noh Asbestos e Structures Sensitivity Concentration Sample KoluiHe Aiialyzeti Ash Typefs) 0.3^S Sp (S/cc) (S/mm') (S/cc) Notes
PH-OI 3850.00 0 1236 3 Nonehelecled 0 0 0 0008 <809 <0.0008 Cellulose-3 Slwdures SM -I
PH-02 3840 00 0.1236 Nona Detected 0 0 OOOOS <8 09 <0 0008 Cellulose - 4 Structures S94'}..,
PH.03 3830.00 0.1236 3 None Detected 0 0 0.0008 <8.09 <0.0008 Cetlutose • 3 Snioures S943. <I
PH-04 3820 00 0.1236 1 Naoe Detected 0 0 0.0008 <8.09 <0.0008 Cellulose • 1 Sbuetures 994} -4
PH-05 3810 00 0.1236 1 None Detected 0 0 0-0008 <8.09 <0.0008 Cellulose -1 Structures S94i -j
12N-06 3820.00 0,1236 1 None Detected 0 0 O.OOOS <8.09 <0.0008 Cstluloae -1 Structures S943. .(
12N-07 3810.00 0.1236 0 None Detected 0 0 0 0008 <8.09 <0.0008 ’?9-I3 .7 ,
MARK PEYSAKHOV MICHAEL A GORVCKl, Ph D
Analyzed by; Approved by.
--------------------------------------- - --------------------------------------- ------------------------------- —______ --------- ------ Oisdaimer. The isbotateiy It not lespontiOie tot data reported In StfUduras/ct, which is dependent on volume coReoted by non-Uboralory penonnei. This tab Is only responsible । ter data reported In structuias/mm'. This report may rot be lepmdueed. except in ten, wiiheur written approval by ATC Associates Ino. This report may not be used to claim | product endorsement fay NVLAP or any other agency of the U.S. Government This reports relates only to Ihe samples reported above. Quality comm data (Includinc 95% ; I confidence Rmits and laboratory and analyse' accuracy and precisian; is avafeMe upon request
AccMdited ter NVLAP PLMOEM #101187-0, NY Sate ELAP#10873
Ptige I of 6
CITY_21MC100_009369505
NYC-WTC_000265652
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000369041
TEM asbestos analysis performed; project cleanup details and samples listed.
6 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265498
TEM asbestos analysis report for DEP cleanup project at 125 Cedar Street.
5 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000181831
Laboratory report detailing transmission electron microscopy results for air samples from the DEP Clean-up project at 125 Liberty Street received on October 8, 2002.
5 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265660
TEM analysis data and metadata for asbestos samples in the cleanup project.
6 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265537
Asbestos TEM analysis for DEP cleanup at 125 Cedar Street, Oct 2002.
6 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265497
TEM asbestos analysis report for project at 125 Cedar Street; AHERA method.
4 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369049
TEM asbestos analysis results and sample data for 125 Cedar Street.
6 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265505
Asbestos fiber analysis by TEM for DEP cleanup project at 125 Cedar Street, Oct 2002.
6 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265634
Asbestos fiber analysis by TEM for DEP Cleanup project, AHERA protocol.
4 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000097135
Transmittal letter accompanies clearance test results for floors five through the lobby of 125 Cedar Street.
6 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107288
Automated fax transmission journal record from the New York City Department of Environmental Protection dated October 23, 2002.
6 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000097110
Fragmented document page containing illegible text and a reference number associated with the World Trade Center cleanup.
6 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000369041
TEM asbestos analysis performed; project cleanup details and samples listed.
Similar indexed content
NYC-WTC_000097135
Transmittal letter accompanies clearance test results for floors five through the lobby of 125 Cedar Street.
Similar indexed content
NYC-WTC_000265498
TEM asbestos analysis report for DEP cleanup project at 125 Cedar Street.
Similar indexed content
NYC-WTC_000107288
Automated fax transmission journal record from the New York City Department of Environmental Protection dated October 23, 2002.
Similar indexed content
NYC-WTC_000097110
Fragmented document page containing illegible text and a reference number associated with the World Trade Center cleanup.
Similar indexed content