NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone: (212^ 353-8280 Fax: (212) 353-8306
wc
Attn: Fred Burkhardt Received: 9/19/02 8:00:00 AM
ATC Associates Inc. ATC Group#: 8861
104 East 25th Street Analysis Date: 9;21/02
New York NY 10010
Fax: (212) 353-3599 Phone: (212) 353-8280
Project: DEP Cleaan-up Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample Volume Analyzed Asb Type(s) O.Sfi-S 5fi (S/cc) (S/mm^) (S/cc) Notes
01 1440.00 0.0562 0 None Detected 0 0 0.0048 <17.79 <0.0048
836/ -/
02 ■ 0.0562 0 None Detected 0 0 0.0048 <17.79 <0.0048
1.440.00
886/,. ■:
03 1446 00 0,0562 0 None Detected 0 0 0.0047 <17.79 <0.0047
886/ -3
04 • 1446.00 0.0562 0 None Detected 0 0 0.0047 <17.79 <0.0047
2861 -4
05 . 1452.00 00562 0 None Detected 0 0 0.0047 <17.79 <0.0047
8861 -5
06 1330.00 0.0674 0 None Detected 0 0 0.0041 <14.83 <0.0041
886! -3
0^ 1380.00 0.0674 0 None Detected 0 0 0.0041 <14.83 <0.0041
iitd/ -
MICHAEL A. GORYCKI, Ph.D
MARK PEYSAKHOV
Analyzed by Approved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is on.y responsible
for data reported in stioctures/mmL This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited ter NVLAP PLM/TEM #101187-0, NY State EAP #10879
Page I of 2